FieldIdentifier is set only on initialization

In TelerikSelectBase that the DropDownList inherits, the FieldIdentifier is set only in the OnInitializedAsync method and therefore the FieldIdentitier is never updated. This can cause issues with validation as seen in this example:  https://blazorrepl.telerik.com/GyamPdlf37LXpPAW36.

To reproduce:

  • Select the last item in the tree 7.Garden and change the value in the drop down list to Unsupported - the drop down list shows a red border.
  • Select item 6.Garden from the tree. (Any item in the tree other than 1 will do) - I expect the drop down to not have the red border, yet is does.

For reference, in the TelerikInputBase, the FieldIdentifier is set in the SetParameterAsync and thus it is accordingly updated. See the TextBox behavior in the above sample.