Under Review
Last Updated: 12 May 2020 11:43 by ADMIN
Ray
Created on: 11 May 2020 19:22
Type: Bug Report
0
Some MouseClick:LeftClick annotations do not go away

See the screen shot.

There are two annotation markers. For some reason, a "MouseClick:LeftClick" will appear, as it should, but then it sticks there, even as 10 or 12 other steps execute and their annotations come and go. Sometimes another MouseClick:LeftClick will appear and the old one will go away and then the new one will stick. But this does not happen every times. Sometimes a new MouseClick:LeftClick annotation comes in and goes away and the old one is still hanging around.

This happens will almost all of my scripts.

Is it because some of the mouse clicks are from recorded steps and some are from code steps? This is just a guess.

1 comment
ADMIN
Elena
Posted on: 12 May 2020 11:43

Hello Ray,

Thank you for the thorough description of the inconsistency you spotted in the annotated runs. 

The misbehavior with the stuck DekstopClick annotation seems to be an issue on our end and with your help we managed to reproduce this. Therefore I converted the current item into a bug report and posted in to our public feedback portal - here is the item, which you can vote for. 

In addition and as a small token of gratitude from our side, I have granted your Telerik account with 500 bonus points. 

Thank you once again for drilling down the annotations, which stick on the screen.

Regards,
Elena
Progress Telerik

Progress is here for your business, like always. Read more about the measures we are taking to ensure business continuity and help fight the COVID-19 pandemic.
Our thoughts here at Progress are with those affected by the outbreak.