Completed
Last Updated: 18 Jan 2024 09:12 by ADMIN
Lindlee
Created on: 15 Dec 2023 09:08
Type: Bug Report
0
Specific scheduled job settings cause Test Studio to freeze on the Results tab

In a project which is not connected to a Scheduling service create a scheduled test list run recurring for the "1st Monday of each Month" with no end dates. This automatically switches to the Results tab but it freezes and you can only exit Test Studio. 

Error in log is as follows:

[12/13 14:02:00,Telerik.TestStudio.exe(12028:34),Error] App.LogUnhandledException() : EXCEPTION! (see below)
     Situation: Unhandled exception!
     Outer Exception Type: System.ArgumentOutOfRangeException
     Message: The added or subtracted value results in an un-representable DateTime.
          Parameter name: value
     HRESULT: 0x80131502 (Official ID (if app.) = COR_E_ARGUMENTOUTOFRANGE, Error Bit = FAILED, Facility = FACILITY_URT, Code = 5378)
     Call Stack:
          at System.DateTime.AddTicks(Int64 value)
0 comments