Currently SvgImage does not support the following inner animation:
<svg xmlns="http://www.w3.org/2000/svg"
A compilation error occurs in a class library project which doesn't use any Telerik code, but it is referenced in another project which installs the Telerik.Licensing NuGet package. The error reproduces only if the class library project contains .xaml files.
The error message from the class library project is the following:
C:\WINDOWS\Microsoft.NET\Framework\v4.0.30319\Microsoft.WinFx.targets(268,9): error MC1000: Unknown build error, 'Cannot resolve dependency to assembly 'Telerik.Licensing.Runtime, Version=1.4.6.0, Culture=neutral, PublicKeyToken=keyhere' because it has not been preloaded. When using the ReflectionOnly APIs, dependent assemblies must be pre-loaded or loaded on demand through the ReflectionOnlyAssemblyResolve event.'
To workaround this, you can add assembly references to the Telerik dlls in the main project (including Telerik.Licensing.Runtime), instead of using NuGet packages.
Alternatively, you can install the Telerik.Licensing NuGet package also in the class library.
<ItemGroup>
<PackageReference Include="Telerik.Licensing" Version="1.4.*" />
</ItemGroup>
Note that with this approach you will see a message in the output that no license is installed, even if you have one. However, for now (versions from 1.4.6 to 1.4.12, which is the latest at the moment of writting this post), the error won't apply any compile or runtime restrictions on the UI or the functionality.
We are using the RadRichTextbox limiting the width size and configured to wrap the text, automatically increasing its height as needed. While this functionality works correctly for most text, it fails in cases where a line ends with spaces. These trailing spaces extend beyond the control's visible boundaries, making them invisible on-screen, yet they remain present in the RadDocument.
To reproduce: Create a RadRichTextbox with limited width and auto adjusted height. Type in underlined text on first line and add a lot of spaces that go behind the visible width. Type in more text to see the visible underlined text go to the next line (while hiding the added underlined spaces of the previous line). Exporting to RadDocument shows the extra underlined spaces that RadRichTextbox does not.
Currently the Windows 11 theme for Telerik WPF features the ability to switch backdrop material to Acrylic, Mica and None, but what it's missing the Mica ALT material.
Because of the substantial difference from the normal Mica material, and the ability it gives to create more modern looking applications we think that the addition of this backdrop material would greatly benefit an already very good looking theme!
Enable the customers to create and modify .pptx (PowerPoint) files . They need processing as well as showing such documents.
Hi,
I would like to report that Z-index have unexpected values when RadDiagramContainerShape are used.
Please watch video first, my remarks points to the video attached to the ticket.
1. Currently there is a possibility that Container A can be hidden by Container B and this is fine.(~11sec of movie)
2. However then i will add Container C to Container A and then drag Container B to overlaps Container A it overlaps only Container A and does not overlaps Container C which for end-user could be very confusing, why Container C is visible at that time.(~20-30 sec of movie)
The problem gets more complicated when i drop Container B to overlaps Container A but without adding Container B as a child of Container A.
In that way it looks that children of Container A are children of Container B
3. When i will add new container "Header" to Container B and then overlaps Container A and Container C then its even more mixed up(~ 30-50 sec of movie)
4. When i will add new container "Header" to Container A and Z-index are somehow refreshed and then in magic way Container_C now overlaps "Header" container from Container B(~58sec of movie)
I would expect:
Fix calculation of Z-index in that way if Container B overlaps Container A it means it overlaps as well it's children. Currently you have flat hierarchy of VMI containers which leads to such Z-index issues.
OR
Expose possibility to override your internal methods which calculates the Z-index.
Hi,
I would like to report that automatic generate of connection point for Bezier connection is wrongly generated when link is attached to Gliding Connector.
Connection point is generated at the position where link is attached to shape. I think for such use-case you should generate connection point taking into account angle of link in relate to shape and generate connection point a bit moved. When connection point is generated at attach position it makes that the "arrow" of link have wrong angle.
I'm attaching video and your sample solution with my modifications to easier reproduction.
Best regards,
BH
Create NuGet symbol packages - containing the .pdb files - corresponding to the primary NuGet packages. The process is described here: https://docs.microsoft.com/en-us/nuget/create-packages/symbol-packages . This will facilitate the debugging of problems in the controls code.
It is possible for a user to type a value into a RadNumericUpDown control that is greater than the maximum (or smaller than the minimum).
If the control loses focus the value reverts to the maximum value, but in my use case the user will be clicking the OK button on a Window, and this happens while the NumericUpDown still displays the out of range value that was typed. In other words the user doesn't realise that their value was silently rejected behind the scenes.
To solve this I had to raise a support request with you guys, which meant waiting until the next day for a resolution. This cost me time and it also added to your workload.
Whereas if the control had the option to limit the user input to the bounds of minimum and maximum it would have saved me about half a days work to raise a support request and write my own solution to the problem.
I see this has been raised a couple of times in the forums:
https://www.telerik.com/forums/prevent-user-from-typing-beyond-maximum-value
https://www.telerik.com/forums/radnumericupdown-lets-you-type-beyond-its-maximum-value
And the consensus seems to be that it is "By Design".
Please can you re-consider changing this as it is these small niggles that often cost us the most time when developing with 3rd party controls.
TIA
Use Case
our users have the possibility to save and load their own RadGridView filter settings.
One user want to get all entries where the value of the property \ column "CreateionDateUtc" is older than 90 days.
Problem
Currently you can only configure Is Less Than "Fixed Date". That means you have to change the "Fixed Date" every day to get the required result.
Is there a possibility to add a filter to the DateTime Column for example Less than 90 Days?
Possible Solution
Possibility to add a Time Difference Filter
- Base (Datetime.Now, Datetime.UtcNow,.....)
- Unit (second, minutes, day, month, years,....)
- Count