private void UpdateHeadersFooters(RadDocument document) { foreach (Section section in document.Sections) { if (section.Headers.Default.Body != null) { this.UpdateFields(section.Headers.Default.Body); } if (section.Headers.First.Body != null) { this.UpdateFields(section.Headers.First.Body); } if (section.Headers.Even.Body != null) { this.UpdateFields(section.Headers.Even.Body); } if (section.Footers.Default.Body != null) { this.UpdateFields(section.Footers.Default.Body); } if (section.Footers.First.Body != null) { this.UpdateFields(section.Footers.First.Body); } if (section.Footers.Even.Body != null) { this.UpdateFields(section.Footers.Even.Body); } } } private void UpdateFields(RadDocument radDocument) { RadDocumentEditor editor = new RadDocumentEditor(radDocument); editor.ChangeAllFieldsDisplayMode(FieldDisplayMode.Code); }
See attached picture together with these steps.
Thanks in advance!
Bart
Steps to reproduce
Unfortunately due to the other cursor jumping bug our users are extremely sensitive to anything that makes it appear like the cursor is not in the position they moved it to.
I attached a gif of this happening with the zoom set to 500% so it is easiest to see but it appears to be a problem at any zoom level 100% or higher.
For example, when DateTimePicker.FlowDirection=RightToLeft, the CalendarIcon is inverted [Windwos8, Greeen, Office2013 etc. themes].
We have a WCF service that continuously polls a database for new/updated items and sends them to WPF clients. The client will process the update, decide what to do and then add/update an item that is displayed in a RadGridView. We use an IEditableCollectionView on top of an ICollectionView. Exception detail is below. App just crashed while sitting idle on Zarate, No mention of MSCORLIB so I think its a different error. Application: ReView.exe Framework Version: v4.0.30319 Description: The process was terminated due to an unhandled exception. Exception Info: System.ArgumentOutOfRangeException at System.ThrowHelper.ThrowArgumentOutOfRangeException(System.ExceptionArgument, System.ExceptionResource) at Telerik.Windows.Data.KeyedCollection.IndexOf(System.Object) at Telerik.Windows.Controls.DataControl.ItemCoerce(System.Windows.DependencyObject, System.Object) at System.Windows.DependencyObject.ProcessCoerceValue(System.Windows.DependencyProperty, System.Windows.PropertyMetadata, System.Windows.EntryIndex ByRef, Int32 ByRef, System.Windows.EffectiveValueEntry ByRef, System.Windows.EffectiveValueEntry ByRef, System.Object ByRef, System.Object, System.Object, System.Windows.CoerceValueCallback, Boolean, Boolean, Boolean) at System.Windows.DependencyObject.UpdateEffectiveValue(System.Windows.EntryIndex, System.Windows.DependencyProperty, System.Windows.PropertyMetadata, System.Windows.EffectiveValueEntry, System.Windows.EffectiveValueEntry ByRef, Boolean, Boolean, System.Windows.OperationType) at System.Windows.DependencyObject.SetValueCommon(System.Windows.DependencyProperty, System.Object, System.Windows.PropertyMetadata, Boolean, Boolean, System.Windows.OperationType, Boolean) at System.Windows.DependencyObject.SetValue(System.Windows.DependencyProperty, System.Object) at Telerik.Windows.Controls.DataControl.Telerik.Windows.Data.Selection.ISelectorInternal.set_CurrentItem(System.Object) at Telerik.Windows.Data.Selection.ItemSelectionHandler.SynchronizePublicCurrentItem() at Telerik.Windows.Data.Selection.ItemSelectionHandler.HandleCurrentItemChanged() at Telerik.Windows.Controls.GridView.Selection.CompositeSelectionHandler+<>c__DisplayClass6.<OnOwnerItemsCurrentChangedDispatch>b__4() at System.Windows.Threading.ExceptionWrapper.InternalRealCall(System.Delegate, System.Object, Int32) at System.Windows.Threading.ExceptionWrapper.TryCatchWhen(System.Object, System.Delegate, System.Object, Int32, System.Delegate) at System.Windows.Threading.DispatcherOperation.InvokeImpl() at MS.Internal.CulturePreservingExecutionContext.CallbackWrapper(System.Object) at System.Threading.ExecutionContext.RunInternal(System.Threading.ExecutionContext, System.Threading.ContextCallback, System.Object, Boolean) at System.Threading.ExecutionContext.Run(System.Threading.ExecutionContext, System.Threading.ContextCallback, System.Object, Boolean) at System.Threading.ExecutionContext.Run(System.Threading.ExecutionContext, System.Threading.ContextCallback, System.Object) at MS.Internal.CulturePreservingExecutionContext.Run(MS.Internal.CulturePreservingExecutionContext, System.Threading.ContextCallback, System.Object) at System.Windows.Threading.DispatcherOperation.Invoke() at System.Windows.Threading.Dispatcher.ProcessQueue() at System.Windows.Threading.Dispatcher.WndProcHook(IntPtr, Int32, IntPtr, IntPtr, Boolean ByRef) at MS.Win32.HwndWrapper.WndProc(IntPtr, Int32, IntPtr, IntPtr, Boolean ByRef) at MS.Win32.HwndSubclass.DispatcherCallbackOperation(System.Object) at System.Windows.Threading.ExceptionWrapper.InternalRealCall(System.Delegate, System.Object, Int32) at System.Windows.Threading.ExceptionWrapper.TryCatchWhen(System.Object, System.Delegate, System.Object, Int32, System.Delegate) at System.Windows.Threading.Dispatcher.LegacyInvokeImpl(System.Windows.Threading.DispatcherPriority, System.TimeSpan, System.Delegate, System.Object, Int32) at MS.Win32.HwndSubclass.SubclassWndProc(IntPtr, Int32, IntPtr, IntPtr) at MS.Win32.UnsafeNativeMethods.DispatchMessage(System.Windows.Interop.MSG ByRef) at System.Windows.Threading.Dispatcher.PushFrameImpl(System.Windows.Threading.DispatcherFrame) at System.Windows.Application.RunDispatcher(System.Object) at System.Windows.Application.RunInternal(System.Windows.Window) at ReView.App.Main() Event Type: Error Event Source: .NET Runtime Event Category: None Event ID: 1026 Date: 10/12/2018 Time: 10:10:15 AM User: N/A Computer: NRAD-NE-RAPAC.ratc.com Description: Application: ReView.exe Framework Version: v4.0.30319 Description: The process was terminated due to an unhandled exception. Exception Info: System.ArgumentOutOfRangeException at System.ThrowHelper.ThrowArgumentOutOfRangeException(System.ExceptionArgument, System.ExceptionResource) at System.Collections.Generic.List`1[[System.__Canon, mscorlib, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089]].get_Item(Int32) at Telerik.Windows.Data.ListExtensions.BinarySearch[[System.__Canon, mscorlib, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089]](System.Collections.Generic.IList`1<System.__Canon>, System.__Canon, System.Func`3<System.__Canon,System.__Canon,Int32>) at Telerik.Windows.Data.KeyedCollection.IndexOf(System.Object) at Telerik.Windows.Controls.DataControl.ItemCoerce(System.Windows.DependencyObject, System.Object) at System.Windows.DependencyObject.ProcessCoerceValue(System.Windows.DependencyProperty, System.Windows.PropertyMetadata, System.Windows.EntryIndex ByRef, Int32 ByRef, System.Windows.EffectiveValueEntry ByRef, System.Windows.EffectiveValueEntry ByRef, System.Object ByRef, System.Object, System.Object, System.Windows.CoerceValueCallback, Boolean, Boolean, Boolean) at System.Windows.DependencyObject.UpdateEffectiveValue(System.Windows.EntryIndex, System.Windows.DependencyProperty, System.Windows.PropertyMetadata, System.Windows.EffectiveValueEntry, System.Windows.EffectiveValueEntry ByRef, Boolean, Boolean, System.Windows.OperationType) at System.Windows.DependencyObject.SetValueCommon(System.Windows.DependencyProperty, System.Object, System.Windows.PropertyMetadata, Boolean, Boolean, System.Windows.OperationType, Boolean) at System.Windows.DependencyObject.SetValue(System.Windows.DependencyProperty, System.Object) at Telerik.Windows.Controls.DataControl.Telerik.Windows.Data.Selection.ISelectorInternal.set_CurrentItem(System.Object) at Telerik.Windows.Data.Selection.ItemSelectionHandler.SynchronizePublicCurrentItem() at Telerik.Windows.Data.Selection.ItemSelectionHandler.HandleCurrentItemChanged() at Telerik.Windows.Controls.GridView.Selection.CompositeSelectionHandler+<>c__DisplayClass6.<OnOwnerItemsCurrentChangedDispatch>b__4() at System.Windows.Threading.ExceptionWrapper.InternalRealCall(System.Delegate, System.Object, Int32) at System.Windows.Threading.ExceptionWrapper.TryCatchWhen(System.Object, System.Delegate, System.Object, Int32, System.Delegate) at System.Windows.Threading.DispatcherOperation.InvokeImpl() at MS.Internal.CulturePreservingExecutionContext.CallbackWrapper(System.Object) at System.Threading.ExecutionContext.RunInternal(System.Threading.ExecutionContext, System.Threading.ContextCallback, System.Object, Boolean) at System.Threading.ExecutionContext.Run(System.Threading.ExecutionContext, System.Threading.ContextCallback, System.Object, Boolean) at System.Threading.ExecutionContext.Run(System.Threading.ExecutionContext, System.Threading.ContextCallback, System.Object) at MS.Internal.CulturePreservingExecutionContext.Run(MS.Internal.CulturePreservingExecutionContext, System.Threading.ContextCallback, System.Object) at System.Windows.Threading.DispatcherOperation.Invoke() at System.Windows.Threading.Dispatcher.ProcessQueue() at System.Windows.Threading.Dispatcher.WndProcHook(IntPtr, Int32, IntPtr, IntPtr, Boolean ByRef) at MS.Win32.HwndWrapper.WndProc(IntPtr, Int32, IntPtr, IntPtr, Boolean ByRef) at MS.Win32.HwndSubclass.DispatcherCallbackOperation(System.Object) at System.Windows.Threading.ExceptionWrapper.InternalRealCall(System.Delegate, System.Object, Int32) at System.Windows.Threading.ExceptionWrapper.TryCatchWhen(System.Object, System.Delegate, System.Object, Int32, System.Delegate) at System.Windows.Threading.Dispatcher.LegacyInvokeImpl(System.Windows.Threading.DispatcherPriority, System.TimeSpan, System.Delegate, System.Object, Int32) at MS.Win32.HwndSubclass.SubclassWndProc(IntPtr, Int32, IntPtr, IntPtr) at MS.Win32.UnsafeNativeMethods.DispatchMessage(System.Windows.Interop.MSG ByRef) at System.Windows.Threading.Dispatcher.PushFrameImpl(System.Windows.Threading.DispatcherFrame) at System.Windows.Application.RunDispatcher(System.Object) at System.Windows.Application.RunInternal(System.Windows.Window) at ReView.App.Main() For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: