This behavior is reproducible when the controls are Anchored. In this case, showing the first on a monitor with higher DPI settings will force those controls to be scaled twice.
Hi Telerik team,
Issue: The location of the RadPanel is locked to 0,0 when its AutoSize property is set to True.
How to reproduce (see also attached demo project):
1. Add a RadPanel in a RadForm. Add some controls into the RadPanel.
2. Set the AutoSize property of the RadPanel to True.
3. The panel cannot be moved in the Designer mode. Setting the Location property programmatically doesn't work, either.
The issue exists in the latest version 2021.1.223, but NOT in the old version 2020.1.218. Guess it's related with some recent update.
Thanks,
Yusi