Completed
Last Updated: 01 Nov 2019 14:52 by ADMIN
Release LIB 2019.3.1104

If you set the SelectedIndex after an item is added in the Items or ItemsSource of RadListBox, the selection doesn't work. 

To work this around, use the SelectedItem property instead of SelectedIndex.

Completed
Last Updated: 16 Jul 2019 13:46 by ADMIN
Release LIB 2019.2.722 (7/22/2019)
This behavior is also reproduced in RadFileDialogs in the FileBrowserListBox which inherits RadListBox.

As a workaround you can set the IsScrollIntoViewEnabled property of the RadListBox to false
Completed
Last Updated: 03 Jul 2019 13:21 by ADMIN
Release LIB 2019.2.708 (7/8/2019)
If you host a RadMaskedTextInput control in the listbox items and focus the input, then pressing Space will send the focus to the corresponding RadListBoxItem instead of adding an empty space character into the text input.

To work this around, create a custom RadListBox control and override its HandleKeyboardInput method.
public class CustomListBox : RadListBox
{
    protected override bool HandleKeyboardInput(Key key)
    {
        if (key == Key.Space)
        {
            return false;
        }
        return base.HandleKeyboardInput(key);
    }
}
Completed
Last Updated: 06 Dec 2018 09:42 by ADMIN
ArgumentOutOfRangeException is thrown when calling the ScrollIntoView method with an invalid index and the control is grouped.

Scheduled for:
The fix for this issue will be available with LIB (version 2018.3.1210) scheduled for publishing on Monday, 10th December 2018.
Completed
Last Updated: 07 Jun 2018 06:35 by ADMIN
Completed
Last Updated: 07 Jun 2018 06:33 by ADMIN
Completed
Last Updated: 08 Mar 2018 09:04 by ADMIN
When the ItemsPanel of the RadListBox is RadWrapPanel and the user press Down/Up key the RadListBox selects always the next/previous item instead of the corresponding item on the next/previous row.
Completed
Last Updated: 08 Feb 2018 15:03 by ADMIN
Available in LIB version 2018.1.205, it will be also available in the R1 2018 SP2 Release.
Completed
Last Updated: 05 Sep 2017 06:08 by ADMIN
As a workaround, the ScrollingSettingsBehavior.ScrollStep attached property of the RadListBox control can be set to a value equal to that of the Height of the RadListBoxItems.

Available in R3 2017 Official Release Version.
Completed
Last Updated: 05 Sep 2017 06:06 by ADMIN
Available in R3 2017 Official Release Version.
Completed
Last Updated: 27 Feb 2017 08:28 by ADMIN
ADMIN
Created by: Nasko
Comments: 0
Category: ListBox
Type: Bug Report
1
Available in the R1 2017 SP1 Release.
Completed
Last Updated: 25 Oct 2016 13:58 by ADMIN
Available with the R3 2016 SP1 release. 
Completed
Last Updated: 17 Oct 2016 15:00 by Ron Frick
Completed
Last Updated: 17 Oct 2016 14:57 by ADMIN
When the ItemsPanel is set to VirtualizingStackPanel which Orientation is set to Horizontal, selecting an item moves it to the rightmost position.

Available in LIB version 2016.3.1017, it will be also available in the 2016 R3 SP1 release. 
Completed
Last Updated: 25 May 2016 14:44 by ADMIN
For example if there are the following items: "Item", "Item 2", "Item 3"
when the RadListBox has the focus typing "Item 2" does not highlight the corresponding item in the ListBiox control.

Available in LIB version 2016.2.525, it will be also available in the 2016 R2 SP1 release.
Completed
Last Updated: 25 May 2016 14:43 by ADMIN
Available in LIB version 2016.2.525, it will be also available in the 2016 R2 SP1 release.
Completed
Last Updated: 28 Apr 2016 15:26 by ADMIN
The "auto scroll into the view on selection" functionality does not to work as expected if the ItemsPanel is changed and a selection was previously done.
Completed
Last Updated: 21 Mar 2016 19:08 by ADMIN
1 2