Declined
Last Updated: 22 Mar 2019 12:48 by ADMIN
Created by: Marco
Comments: 2
Category: Docking
Type: Feature Request
1

Having Problems with unreadable Tabs in RadPaneGroup: TabsSqueeze.png

I think I found a Solution with OverflowMode and ScrollViewer:

<telerik:RadPaneGroup x:Name="DocumentGroup" ScrollViewer.HorizontalScrollBarVisibility="Auto" OverflowMode="Scroll">

Problem:

After Loading Layout the OverflowMode is not respected anymore.

I found this ticket in Silverlight, what discribes the Problem and is approved: Docking: I would like OverflowMode to work for all RadPaneGroup in xaml/codebehind and this be persisted through SaveLayout/LoadLayout

And i found this documentation, which say, using OverflowMode can lead to unexpected behaviors:
https://docs.telerik.com/devtools/wpf/controls/raddocking/general-information/not-supported-properties

so i report this as a feature instead of a bug.

Please sea atteched an example project: TabWrapProblem.zip
Usage: Save and than Load the Layout -> Scrolling of tabs break

Declined
Last Updated: 25 Jan 2019 17:33 by ADMIN

After upgrading to Telerik WPF 2019.1.116 from 2018.3.1010 we receive a lot of:

System.ComponentModel.Win32Exception (0x80004005): Invalid window handle
   MS.Win32.UnsafeNativeMethods.GetWindowText(HandleRef hWnd, StringBuilder lpString, Int32 nMaxCount)

Exceptions. It makes out application very slow.

In version 2018 everyting was OK. See attached scerenshots.

Declined
Last Updated: 05 Jan 2017 15:23 by ADMIN
Declined
Last Updated: 05 Jan 2017 15:18 by ADMIN
Declined
Last Updated: 28 Dec 2016 19:45 by ADMIN
Created by: Sherry
Comments: 4
Category: Docking
Type: Bug Report
0
Got this weird behavior with RadDocking with multiple monitors.

http://www.youtube.com/watch?v=8DDX5OiYRyM

As you could see the pane is being opened on the wrong side.

This happens only when the application is fully maximized, if its resized then this problem does not occur.

I am not able to reproduce this with a simple example. But you could contact me I can help in investigation.
Declined
Last Updated: 20 Dec 2016 12:53 by ADMIN
Created by: Michael
Comments: 2
Category: Docking
Type: Bug Report
1

			
Declined
Last Updated: 20 Oct 2016 10:50 by ADMIN
Created by: Ravikant
Comments: 1
Category: Docking
Type: Feature Request
0
Is there any option to create a connection line as a blank rectangle. At present I can see only solid lines only. Please see the attached image, and suggest how to get top two connection types.

Decline reason: The diagram exposes an API that allows you to create custom geometry for the connection. You can override the CreateGeometry(), CreateSourceCapGeometry() and CreateTargetCapGeometry() methods of RadDiagramConnection and create custom geometries. See the CustomConnectionCap SDK example: https://github.com/telerik/xaml-sdk/tree/master/Diagram/CustomConnectionCaps
Declined
Last Updated: 17 Aug 2016 08:23 by ADMIN
Declined
Last Updated: 11 Aug 2016 14:05 by ADMIN
Declined
Last Updated: 11 Aug 2016 14:04 by ADMIN
The text in the Alt+Tab Manager is empty when there is a floating Pane in Windows XP
Declined
Last Updated: 25 May 2016 14:17 by ADMIN
If a SplitContainer's InitialPosition is set to FloatingDockable and the the layout is saved in the Unloaded event of the control, that SplitContainer is not shown after layout load.

The same could be observed if you float a Pane by dragging it out of its docked state.
Declined
Last Updated: 22 Jan 2016 13:11 by ADMIN
When all of the RadDocument panes in the DocumentHost are closed the last one stays alive in .Net Framework 4.0. The issues can't be reproduced on machines with .Net Framework 4.5 installed
Declined
Last Updated: 02 Dec 2015 15:48 by Tobias
ADMIN
Created by: Nasko
Comments: 4
Category: Docking
Type: Bug Report
1

			
Declined
Last Updated: 29 Jun 2015 16:23 by ADMIN
Declined
Last Updated: 23 Apr 2015 15:14 by ADMIN
Panes that are autohidden are cut if resized too much - this is due to limitation in WPF that popups should not cover more than 75% of the screen.
Declined
Last Updated: 18 Feb 2015 08:29 by ADMIN
RadPane setting CanFloat, CanUserPin & CanUserClose to false, ContextMenuTemplate="{x:Null}" and PaneHeaderVisibility="Collapsed" still leaves a small part of the header visible and clickable. If there is any work-around can you please let me know. Version 2014.3.1202.45, using Framework 4.5 with VS2013.
Declined
Last Updated: 14 Jan 2015 16:08 by ADMIN
Declined
Last Updated: 05 Nov 2014 09:55 by ADMIN
An access key can be added to ContentPresenter in WPF if you add underscore in the content and set RecognizeAccessKey to true.If the ContentPresenter is inside DocumentHost, the access key is working, but the underscore in the UI is not visible. If you remove the DocumentHost everything works as expected.
Declined
Last Updated: 01 Apr 2014 14:48 by ADMIN
Created by: Kiranjeet
Comments: 1
Category: Docking
Type: Feature Request
2
I have a scenario where I only want to unhide the pane when certain property of the document is true.

For example: I have 3 panes A,B and C

Panes A and C are visible.

Active Pane should always be Pane A.

By default pane (B) is hidden.

Now when I set the IsHidden Property of the pane B to FALSE. Pane B now becomes the active pane.

I still want Pane A to be the Active Pane, but show the Pane B in background.

If I try setting the Pane A to be the active pane after Pane B is shown. It flickers which you can see here http://screencast.com/t/dGvU7UwUyYp

Is there any way i can unhide the pane in background while the active pane remains the same without having this flickering scenario.
Declined
Last Updated: 17 Mar 2014 09:07 by ADMIN
Exception is thrown when running RadDocking in separate thread.
1 2