Approved
Last Updated: 03 Dec 2019 14:47 by ADMIN
Prevent the closing of the auto-hide area if the context menu of an element in it is opened.
Approved
Last Updated: 01 Nov 2019 09:21 by ADMIN

This feature request is related to Ticket 1435779

 

Image for context

 

Currently, there's no support for increasing the drag threshold for the items on the orange box. Even after setting the values below.

DragDropManager.MinimumHorizontalDragDistance = 5000;
DragDropManager.MinimumVerticalDragDistance = 5000;

 

It would also be beneficial if instead of just relying on the drag threshold which is the box. Add a support for a sort of "Drag Time" concept where we can define how long the user should've held the actual pane before dragging/going outside the threshold.

Approved
Last Updated: 28 Dec 2018 08:39 by ADMIN
The RadDocking control template hosts several AutoHideArea elements, one for each auto-hide placement - left, top, right, bottom. When you unpin a RadPane, it goes into one of those areas. The active auto-hide area where the pane will go is determined by the State of the topmost RadSplitContainer.

Allow manually setting the auto-hide area where the RadPane will go when unpinned.
Approved
Last Updated: 21 Nov 2018 16:55 by ADMIN
The RadPaneGroup inherits RadTabControl and the TabStripPlacement property. Currently the RadPaneGroup does not support setting this property as the corresponding ControlTemplates are not implemented.
Approved
Last Updated: 19 Apr 2018 10:15 by Vladimir
Approved
Last Updated: 22 Mar 2018 13:05 by ADMIN
Approved
Last Updated: 15 Mar 2019 17:39 by ADMIN
Approved
Last Updated: 03 Jan 2017 21:16 by ADMIN
ADMIN
Created by: Georgi
Comments: 0
Category: Docking
Type: Feature Request
0

			
Approved
Last Updated: 03 Jan 2017 21:09 by ADMIN
ADMIN
Created by: Georgi
Comments: 0
Category: Docking
Type: Feature Request
0
    After starting the application, there are 2+ RadPane instances
    Each RadPane contains multiple TextBox controls
    Click on a TextBox in first RadPane
    Switch to the next RadPane
    go back to the first RadPane

The desired behavior is that the focus is restored to the focused element in step 3. Currently no element is focused. The same scenario in RadTabControl is a bit different and the TabControl focused the first element in its TabItem content.
Approved
Last Updated: 15 Mar 2019 17:39 by ADMIN
Approved
Last Updated: 15 Mar 2019 17:39 by ADMIN
Just like in Visual Studio, a floating pane, which I want to dock (for example to the bottom), can either take the whole width or just the width that is left.

For example:
At start, the panes in the bottom does not consume the whole window width. After undocking the panes and docking them back, the compass only shows me an option to dock the panes while consuming the whole width.

I have no option to return to the original state (like in Start.png). The only way to return to that state is undock and re-dock the right pane, and then dock and re-dock the left pane.

Visual Studio has this feature (see image).
Approved
Last Updated: 03 Jan 2017 21:12 by ADMIN
Currently when a Pane becomes floating and we are still holding it with the mouse the ToolWindow could not be snapped. First the mouse should be released and right after that the ToolWindow could be snapped.
Approved
Last Updated: 15 Mar 2019 17:39 by ADMIN
Provide an easy functionality to exclude a pane or group of panes from reordering when AllowDragReorder is set to True.
Approved
Last Updated: 03 Aug 2016 12:52 by ADMIN
Approved
Last Updated: 03 Jan 2017 21:13 by ADMIN
When loading a previously saved layout that includes a floated RadPane located on a currently not available monitor, that RadPane should be made visible on the available monitor.

Currently its is directly loaded in its saved location which is not visible.
Approved
Last Updated: 04 Jan 2017 07:33 by ADMIN
By design in the current version of RadDocking when a hidden RadPane instance in a RadPaneGroup is made visible by changing the IsHiddden property of that pane to False, that RadPane is set to be SelectedItem in the group.


Make it possible to disable this functionality. This way the old selected RadPane in that RadPaneGroup will be persisted.
Approved
Last Updated: 03 Jan 2017 20:53 by ADMIN
Pinning a pane instance will cause that instance's tab to go to the first place of the group in which it is in the DocumetnHost of the control. This behavior could be observed in MS Visual Studio 2013
1 2 3