Approved
Last Updated: 19 Apr 2018 10:15 by Vladimir
Approved
Last Updated: 22 Mar 2018 13:05 by ADMIN
Completed
Last Updated: 19 Feb 2018 15:07 by ADMIN
The fix will be available in the R1 2018 SP2 Release.
Approved
Last Updated: 15 Mar 2019 17:39 by ADMIN
Completed
Last Updated: 07 Jun 2018 08:31 by ADMIN
Completed
Last Updated: 02 Jan 2018 12:08 by ADMIN
Available in LIB version 2017.3.1225, it will be also available in the R1 2018 Release.
Approved
Last Updated: 10 Nov 2017 18:04 by ADMIN
Approved
Last Updated: 30 Oct 2017 15:02 by ADMIN
Completed
Last Updated: 16 Oct 2017 10:44 by ADMIN
workaround:
add the following visual state to the DocumentHostTemplate of the RadPaneGroup:

<VisualStateManager.VisualStateGroups>
    <VisualStateGroup x:Name="DropDownDisplayStates">
        <VisualState x:Name="DropDownButtonCollapsed" />
        <VisualState x:Name="DropDownButtonVisible">
            <Storyboard>
                <ObjectAnimationUsingKeyFrames Storyboard.TargetName="DropDownButtonElement" Storyboard.TargetProperty="Visibility">
                    <DiscreteObjectKeyFrame KeyTime="0">
                        <DiscreteObjectKeyFrame.Value>
                            <Visibility>Visible</Visibility>
                        </DiscreteObjectKeyFrame.Value>
                    </DiscreteObjectKeyFrame>
                </ObjectAnimationUsingKeyFrames>
            </Storyboard>
        </VisualState>
    </VisualStateGroup>
</VisualStateManager.VisualStateGroups>

and remove the trigger targeting the drop down button.
Completed
Last Updated: 16 Apr 2019 08:16 by ADMIN
Release LIB 2019.1.422 (04/22/2019)
Completed
Last Updated: 31 May 2017 13:02 by ADMIN

Available in LIB version: 2017.2.605
Declined
Last Updated: 20 Dec 2016 12:53 by ADMIN
Created by: Michael
Comments: 2
Category: Docking
Type: Bug Report
1

			
Declined
Last Updated: 28 Dec 2016 19:45 by ADMIN
Created by: Sherry
Comments: 4
Category: Docking
Type: Bug Report
0
Got this weird behavior with RadDocking with multiple monitors.

http://www.youtube.com/watch?v=8DDX5OiYRyM

As you could see the pane is being opened on the wrong side.

This happens only when the application is fully maximized, if its resized then this problem does not occur.

I am not able to reproduce this with a simple example. But you could contact me I can help in investigation.
Completed
Last Updated: 07 Nov 2016 15:04 by ADMIN
Available in LIB version 2016.3.1107, it will be also available in the 2017 R1 release.
Declined
Last Updated: 20 Oct 2016 10:50 by ADMIN
Created by: Ravikant
Comments: 1
Category: Docking
Type: Feature Request
0
Is there any option to create a connection line as a blank rectangle. At present I can see only solid lines only. Please see the attached image, and suggest how to get top two connection types.

Decline reason: The diagram exposes an API that allows you to create custom geometry for the connection. You can override the CreateGeometry(), CreateSourceCapGeometry() and CreateTargetCapGeometry() methods of RadDiagramConnection and create custom geometries. See the CustomConnectionCap SDK example: https://github.com/telerik/xaml-sdk/tree/master/Diagram/CustomConnectionCaps
Completed
Last Updated: 07 Nov 2016 15:02 by ADMIN
Available in LIB version 2016.3.1107, it will be also available in the 2017 R1 release.
Approved
Last Updated: 03 Jan 2017 21:16 by ADMIN
ADMIN
Created by: Georgi
Comments: 0
Category: Docking
Type: Feature Request
0

			
Approved
Last Updated: 03 Jan 2017 21:09 by ADMIN
ADMIN
Created by: Georgi
Comments: 0
Category: Docking
Type: Feature Request
0
    After starting the application, there are 2+ RadPane instances
    Each RadPane contains multiple TextBox controls
    Click on a TextBox in first RadPane
    Switch to the next RadPane
    go back to the first RadPane

The desired behavior is that the focus is restored to the focused element in step 3. Currently no element is focused. The same scenario in RadTabControl is a bit different and the TabControl focused the first element in its TabItem content.