To reproduce:
  RadMessageBox.Instance.Font = new Font("Segoe UI", 10);
            foreach (Control c in RadMessageBox.Instance.Controls)
            {
                c.Font = new Font("Segoe UI", 14);
            }
            RadMessageBox.SetThemeName("TelerikMetro");

            RadMessageBox.Show("test", "test2", MessageBoxButtons.YesNoCancel,                  
            RadMessageIcon.Error, MessageBoxDefaultButton.Button2);

WORKAROUND: use smaller font size
Completed
Last Updated: 09 Oct 2014 12:57 by ADMIN
To reproduce:

Create a RadForm and set the property as follows:

public Form1()
{
    InitializeComponent();
    this.FormBorderStyle = System.Windows.Forms.FormBorderStyle.FixedToolWindow;
}

Workaround:

Set the ShowIcon property to false:

public Form1()
{
    InitializeComponent();
    this.FormBorderStyle = System.Windows.Forms.FormBorderStyle.FixedToolWindow;
    this.ShowIcon = false;
}

Completed
Last Updated: 09 Oct 2014 12:22 by ADMIN
ADMIN
Created by: Martin Vasilev
Comments: 0
Category: Form
Type: Feature Request
1
Option to show RadMessageBox in task bar

Resolution: 

You can use the following code snippet show the message box in the taskbar: 

RadMessageBox.Instance.ShowInTaskbar = true;

Completed
Last Updated: 08 Oct 2014 14:01 by ADMIN
ADMIN
Created by: Georgi I. Georgiev
Comments: 0
Category: Form
Type: Bug Report
3
To reproduce:
Add a RadRibbonBar, associate AcceptButton and CancelButton and subscribe to their events. Run the application press escape and the CancelButton's event should be fired. Press enter -  no results.
Workaround:
protected override bool ProcessCmdKey(ref System.Windows.Forms.Message msg, System.Windows.Forms.Keys keyData)
{
    if (keyData == System.Windows.Forms.Keys.Enter)
    {
        this.AcceptButton.PerformClick();
    }

    return base.ProcessCmdKey(ref msg, keyData);
}

Resolution: 

The issue is fixed in Telerik`s RadForm and RadRibbonForm. If you use MS Form, this is still not working.  
Completed
Last Updated: 01 Oct 2014 12:18 by ADMIN
Workaround: use RadRibbonForm instead or set minimum and maximum size
Completed
Last Updated: 17 Sep 2014 09:07 by ADMIN
To reproduce:

Show RadMessageBox as follows:

RadMessageBox.Show(this, "מסר כלשהו", "Caption", MessageBoxButtons.OKCancel, RadMessageIcon.Error, MessageBoxDefaultButton.Button1, RightToLeft.Yes, "מסר2 כלשהו");

Open the details button and you will see that the text is כלשהו מסר2
Completed
Last Updated: 05 Sep 2014 11:14 by ADMIN
ADMIN
Created by: Stefan
Comments: 0
Category: Form
Type: Bug Report
6
FIX. RadForm text flickers on change
Completed
Last Updated: 05 Sep 2014 08:37 by ADMIN
To reproduce:
- Set the form MinimumSize to or close to the RadForm's actual size.
- Turn all windows visual effects off
- Set the theme to Office2010Silver
- Start the application

Workaround: 
- Load the theme manually in code like this:
 ThemeResolutionService.LoadPackageFile("C:\Office2010Silver.tssp")
 ThemeResolutionService.ApplicationThemeName = "Office2010Silver"
Completed
Last Updated: 24 Jul 2014 07:40 by ADMIN
Steps to reproduce:
1. Add a RadPropertyGrid to a form and subscribe for the PropertyValidating event
2. In the event handler show a RadMessageBox

Run the project and change a property. Try to save the value and you will see an exception.
Completed
Last Updated: 24 Jul 2014 07:40 by ADMIN
After each call to the Show method of RadMessageBox, the message box form is disposed. This causes each new call to Instance (or Show which internally calls Instance) to create a new instance of a message box form, loosing any user settings.
Completed
Last Updated: 24 Jul 2014 07:40 by ADMIN
We should allow users to turn off the sound played when a RadMessageBox is shown.
Completed
Last Updated: 24 Jul 2014 07:40 by Jesse Dyck
To workaround this issue you should dispose the Instance property of RadMessageBox after each show of message box. For example:

WORKAROUND: 
RadMessageBox.Show("Text");
RadMessageBox.Instance.Dispose();

If you are using themes, consider the following approach:
            RadMessageBox.SetThemeName("Windows7");
            RadMessageBox.Show("This is some long text that sometimes does not wrap as it should.");
            var field = typeof(RadMessageBox).GetField("radMessageBoxForm", BindingFlags.NonPublic | BindingFlags.Static);
            field.SetValue(null, null);
Completed
Last Updated: 24 Jul 2014 07:40 by ADMIN
When RadMessageBox has not owner and it is using in form that has TopMost = true throws exception after first call of RadMessageBox.Show()

Steps to reproduce:

1.Create From with TopMost  = true

2. Add button and insert the following code in press event:
RadMessageBox.Show("Text");
3.Run application and press the button two times.

Workaround after each show of RadMessageBox add this code snippet:
RadMessageBox.Instance.Dispose();
Completed
Last Updated: 24 Jul 2014 07:40 by ADMIN
RadMessageBox  throws ArgumentException - "A circular control reference has been made. A control cannot be owned by or parented to itself." when using with MDI forms. 

WorkAround:
RadMessageBox.Show("Text");
RadMessageBox.Instance.Dispose();
Completed
Last Updated: 24 Jul 2014 07:40 by ADMIN
RadMessageBox - SetThemeName method is not working correctly, after dispose on owner form.

Workaround - Reset the radMessageBoxForm field via reflection. For example:

            var field = typeof(RadMessageBox).GetField("radMessageBoxForm", BindingFlags.NonPublic | BindingFlags.Static);
            field.SetValue(null, null);

            RadMessageBox.SetThemeName("Office2007Black");
Completed
Last Updated: 24 Jul 2014 07:40 by ADMIN
ADMIN
Created by: Martin Vasilev
Comments: 0
Category: Form
Type: Bug Report
3
Default button focus is not correct and additional tab press is needed.
Completed
Last Updated: 24 Jul 2014 07:40 by ADMIN
ADMIN
Created by: Georgi
Comments: 0
Category: Form
Type: Bug Report
1
When HTML-formatted text is displayed in RadMessageBox, it is cut off on the right.
Completed
Last Updated: 24 Jul 2014 07:40 by ADMIN
ADMIN
Created by: Boryana
Comments: 0
Category: Form
Type: Feature Request
15
Add a details section to RadMessageBox, so that in mimics standard error messages.
Completed
Last Updated: 24 Jul 2014 07:40 by ADMIN
When you are navigating repeatedly between the buttons in RadMessageBox using the arrow keys, at one of the steps none of the buttons is focused.
Completed
Last Updated: 24 Jul 2014 07:40 by ADMIN
RadMessageBox - Buttons are not arranged correctly in RTL