Completed
Last Updated: 24 Oct 2011 04:41 by ADMIN
FIX. Themes - RadDateTimeEditor have an incorrect gradient color setting.
Completed
Last Updated: 29 Feb 2012 07:06 by ADMIN
IMPROVE - FilterPredicate should allow passing a parameter as argument to the predicate method
implemented new generic Find<> and FindNodes<>, support callbacks amd lamba expression:
public TreeViewSelection()
{
InitializeComponent();
treeView.Dock = DockStyle.Fill;
treeView.Parent = this.panel1;
treeView.MultiSelect = true;
treeView.Nodes.Add("1");
treeView.Nodes.Add("2");
treeView.Nodes.Add("2");
treeView.Nodes.Add("2");
treeView.Nodes[0].Nodes.Add("11");
treeView.Nodes[0].Nodes.Add("12");
treeView.Nodes[0].Nodes.Add("13");
RadTreeNode node = this.treeView.Find<string>(FindName, "11");
node = this.treeView.Find<string>((n, x) => n.Name == x, "12");
}
private bool FindName(RadTreeNode node, string name)
{
if (node.Text == name)
{
return true;
}
return false;
}
Completed
Last Updated: 16 Jan 2012 09:00 by ADMIN
FIX. RadMultiColunmComboBox editable area should look like RadDropDownList editable area
Completed
Last Updated: 29 Oct 2012 09:58 by ADMIN
Office2007Black Theme cannot render the state of a diabled RadCheckBox
Completed
Last Updated: 09 Jul 2014 10:34 by ADMIN
VisualStudio2012Dark theme has incorrect styling for RadLabel. The background color of RadLabel is not consistent with other colors.  
Completed
Last Updated: 11 Feb 2014 16:02 by ADMIN
The NavigateBackwards/Forwards buttons in RadSchedulerNavigator should show image instead of text when using Aqua theme.
Completed
Last Updated: 23 Apr 2014 12:56 by ADMIN
When maximizing child form in MDI container form with Windows8theme applied, the theming of the MDI buttons would be missing.
Completed
Last Updated: 18 Feb 2015 12:57 by Jesse Dyck
Create an MDI application. When you maximize an MDI Child form you will see that the restore button has a maximize icon instead of restore one. This is true for the following themes:
ControlDefault, Office2010Blue, Office2010Black
Completed
Last Updated: 01 Aug 2013 10:36 by ADMIN
ADMIN
Created by: Georgi I. Georgiev
Comments: 0
Category: UI Framework
Type: Feature Request
1
Change the gestures logic so it can be enabled/disabled per-control.

see Control1.SupportsGestures property
Completed
Last Updated: 11 Dec 2010 04:49 by ADMIN
ADMIN
Created by: Nikolay
Comments: 0
Category: UI Framework
Type: Bug Report
1
One should not be able to trigger a shortcut if the element that has the shortcut assigned is disabled.
Completed
Last Updated: 26 Feb 2014 13:56 by ADMIN
ADMIN
Created by: Telerik Admin
Comments: 0
Category: UI Framework
Type: Feature Request
1
Register themes as components
Completed
Last Updated: 14 Jun 2012 06:20 by ADMIN
1. Create a new project with RadCarousel.
2. Add some items.
3. On item click change the current theme.
4. Run the project and click an item.
Completed
Last Updated: 29 Aug 2017 06:11 by ADMIN
How to reproduce: check the attached screenshot

Workaround create a custom RadPrintPreviewDialog
public class MyRadPrintPreviewDialog : RadPrintPreviewDialog
{
    protected override WatermarkPreviewDialog CreateWatermarkDialog()
    {
        WatermarkPreviewDialog dialog = new WatermarkPreviewDialog(this.Document);

        RadPageViewPage pageText = (RadPageViewPage)dialog.Controls["radPageView1"].Controls["pageText"];
        ((PlusMinusEditor)pageText.Controls["plusMinusEditorTextHOffset"]).TextBox.Width = 43;
        ((PlusMinusEditor)pageText.Controls["plusMinusEditorTextVOffset"]).TextBox.Width = 43;
        ((PlusMinusEditor)pageText.Controls["plusMinusEditorTextAngle"]).TextBox.Width = 43;
        ((PlusMinusEditor)pageText.Controls["plusMinusEditorTextOpacity"]).TextBox.Width = 43;
        RadPageViewPage pagePicture = (RadPageViewPage)dialog.Controls["radPageView1"].Controls["pagePicture"];
        ((PlusMinusEditor)pagePicture.Controls["plusMinusEditorImageHOffset"]).TextBox.Width = 43;
        ((PlusMinusEditor)pagePicture.Controls["plusMinusEditorImageVOffset"]).TextBox.Width = 43;
        ((PlusMinusEditor)pagePicture.Controls["plusMinusEditorImageOpacity"]).TextBox.Width = 43;

        return dialog;
    }
}
Completed
Last Updated: 23 Mar 2016 07:02 by JeffSM
ADMIN
Created by: Dess | Tech Support Engineer, Sr.
Comments: 1
Category: UI Framework
Type: Bug Report
1
To reproduce:

string filePath = @"D:\Projects\1015954MenuItemHTML\1015954MenuItemHTML\Resources\calendar.png";
StringBuilder sbItem = new StringBuilder();
sbItem.Append("<html><b>aaa<img src=" + filePath + ">");
sbItem.Append("</html>");

RadMenuItem item = new RadMenuItem();
item.Text = sbItem.ToString();
this.radMenuItem1.Items.Add(item);


Workaround: use resource file: string filePath = @"res:_1015954MenuItemHTML.Resources.calendar.png";
Completed
Last Updated: 08 Jun 2016 10:07 by ADMIN
To reproduce:
- Open the Breeze theme.
- Hover the ScrollBar with the mouse - the background is changed and never restored. 
Completed
Last Updated: 25 Apr 2017 11:53 by ADMIN
At the moment one needs to iterate all controls and set the EnableCodedUITests property individually. It would be nice if there is a way this to be done only once affecting all controls.
Completed
Last Updated: 05 Oct 2016 13:27 by ADMIN
ADMIN
Created by: Stefan
Comments: 2
Category: UI Framework
Type: Bug Report
1
When a child form is opened in a new thread, and tooltips are used in the child form, cross thread exception is thrown, due to the fact that RadToolTip internally uses a static control instance.

 public class ManagedThread
    {
        private Thread _thread;
        public ManagedThread()
        {
            _thread = new Thread(new ThreadStart(OpenNew));
        }

        private void OpenNew()
        {
            Child form = new Child();
            form.Text = "my text";
            form.ShowDialog();
        }
}

The second time the child form is opened, when you try to show tooltips of a control e.g. RadDropDownList with ToolTipTextNeeded, the exception is thrown.

Workaround: use screentips instead of tooltips: http://docs.telerik.com/devtools/winforms/treeview/how-to/assign-radscreentip-to-nodes
Completed
Last Updated: 09 May 2016 10:02 by ADMIN
To reproduce:
Dock a window under another with these themes( blue black silver): instead of docking under, it docks overs as if over the tab icon instead of the down arrow.

Workaround:

-Extract the predefined themes 
-Open the Office2010blue theme with Visual Style Builder
-In the control structure window select RadDock - Docking Guides
-Expand DockingGuidesElement and select BottomImage
-In the Elements window expand DockingGuidesElement and set filter to changed properties
-Change LocationOnCenterGuide property to 45;90
-Save the theme and use it in your application
Completed
Last Updated: 16 Nov 2015 13:24 by ADMIN
FIX. RadRibbonForm - exception when loading icon in design time "Requested range extends past the end of the array."
Completed
Last Updated: 27 Sep 2016 08:19 by ADMIN
To reproduce:
The result of the following line is always null:
var test = ThemeResolutionService.GetTheme(ThemeResolutionService.ApplicationThemeName).FindStyleGroup("Telerik.WinControls.UI.RadLabel");

Workaround:
var test1 = ThemeResolutionService.GetTheme(ThemeResolutionService.ApplicationThemeName).FindStyleGroup(new RadLabel());