Completed
Last Updated: 11 Feb 2014 16:22 by Jesse Dyck
ADMIN
Created by: Julian Benkov
Comments: 3
Category: Dock
Type: Feature Request
13
Visual Studio 2010 document window behavior
Completed
Last Updated: 11 Apr 2019 14:50 by Dimitar
Release R2 2019 (LIB 2019.1.415)
Use attached to reproduce.

Tested on Windows 10 (1607 and 1703)

Workaround:

RadControl.EnableDpiScaling = False

Completed
Last Updated: 24 Feb 2014 10:58 by Jesse Dyck
ADMIN
Created by: Georgi
Comments: 1
Category: Dock
Type: Feature Request
7
Visual Studio 2010 introduced the concept of document windows which behave like a regular tool window. Implement the same functionality within RadDock.
Completed
Last Updated: 26 Feb 2014 13:57 by Jesse Dyck
ADMIN
Created by: Georgi
Comments: 1
Category: Dock
Type: Feature Request
6
When a floating window is hidden and RadDock layout is saved, the hidden window is saved in its Docked state and displayed as Docked when layout is loaded.
Completed
Last Updated: 06 Feb 2015 12:19 by ADMIN
RadDock should have ActiveMDIChild property which returns the currently activated mdi child.

Resolution: 
Use the ActiveMDIChild property of the parent form. 
Completed
Last Updated: 25 Mar 2015 16:27 by ADMIN
ADMIN
Created by: Julian Benkov
Comments: 0
Category: Dock
Type: Feature Request
6
using the RadDock component in a product that must support multiple montors.  I see some mention of this in the support forums, but I would like to confirm with you that RadDock does support docking on multiple monitors with dragging of panes/panels between monitors and full serialization of the layout on multiple displays. Add support to move and maximize DocumentWindow and ToolWindow in multimonitor system.
Completed
Last Updated: 18 May 2011 04:38 by Jesse Dyck
In addition, if this ContextMenu is called from a control contained in an autohide DockWindow that is currently expanded, this window becomes collapsed.
Completed
Last Updated: 05 Jun 2014 07:07 by ADMIN
ADMIN
Created by: Nikolay
Comments: 0
Category: Dock
Type: Feature Request
5
One should be able to drag and drop a ToolWindow to the ToolWindows area even if this ToolWindow is currently docked in the DocumentWindows area, similar to the VS2010 behavior.
Completed
Last Updated: 19 Jun 2017 12:59 by ADMIN
ADMIN
Created by: Dimitar
Comments: 2
Category: Dock
Type: Bug Report
5
To reproduce:
Use the approach here:  http://docs.telerik.com/devtools/winforms/dock/object-model/customizing-floating-windows

Workaround:
private void RadDock1_FloatingWindowCreated(object sender, Telerik.WinControls.UI.Docking.FloatingWindowEventArgs e)
{
    e.Window = new MyWindow(radDock1);
    e.Window.FormBorderStyle = System.Windows.Forms.FormBorderStyle.Sizable;

}

class MyWindow : FloatingWindow
{
    public MyWindow(RadDock dock): base(dock)
    {

    }
    protected override CreateParams CreateParams
    {
        get
        {
            CreateParams cp = base.CreateParams;
            cp.Style |= NativeMethods.WS_THICKFRAME;
            return cp;
        }
    }
}
Completed
Last Updated: 16 Jan 2015 06:04 by ADMIN
A nice addition to the existing save/load layout functionality of RadDock will be the possibility to save the AutoHideSize value.
Completed
Last Updated: 11 Feb 2015 09:57 by ADMIN
If there is a RadDock in UserControl and second UserControl, which inherits the first one, then the RadDock€™s layout in the second UC is damaged in design and run-time.
Completed
Last Updated: 06 Feb 2015 17:02 by ADMIN
It is caused when you open the solution for the first time, open the FrmUmre in design time, change the active window in RadDock and run the application. 

The error states: "The control Telerik.WinControls.UI.Docking.DocumentTabStrip has thrown an unhanded exception in the designer and has been disabled"
Completed
Last Updated: 16 Jan 2015 08:22 by ADMIN
Trying to Double-Click ToolWindow to dock it back on RadDock as a Tab...

When you set a ToolWindow to only AllowedDockStates of Floating,TabbedDocument and Hidden, you lose the header double-click functionality of the toolwindow that pops the ToolWindow out as a floating window as well as pops it back in as a tabbed document. If you add AllowedDockState of Docked, the double-click functionality works. 

I am working with ToolWindows on a RadDock control and want them only represented as either Floating or TabbedDocuments with the ability to double-click a floating window caption and pop it back onto the RadDock control as a TabbedDocument. I got the double-click functionality to pop a floating window back in by using DockStateChanged and TransactionCommitment events. The less important one of double-clicking on a TabbedDocument header to pop it back out I have not yet done.

I use the DockStateChanged event to fire when ToolWindows are set to floating and change the AllowedDockState of that window to use Docked. I use TransactionCommitment to change a ToolWindow's AllowedDockState to exclude Docked and programmatically change the DockState of the window to TabbedDocument. Is this the best approach or did I miss a simple property or something? I pasted the two methods below for your convenience.

Resolution: 

In Q1 2014 (version 2014.1.226) we introduced an floating option for tabbed document which resolved this issue. 
Here is the link to the feedback item: http://feedback.telerik.com/Project/154/Feedback/Details/111942-improve-give-floating-option-for-tabbed-document
Completed
Last Updated: 15 Jan 2015 17:43 by ADMIN
I put a tree on toolwindow (the tree Nodes are chekbox)  , when I autohide the toolwindow and show it again the font of tree nodes change and also the nodes which were checked change to uncheck
Completed
Last Updated: 06 Feb 2015 14:54 by ADMIN
We have a somewhat complicated application in which we have a RadDock inside another RadDock.
Everything seems to work just fine, with one exception.

When we resize the application window itself, the ToolWindow and DocumentWindow controls don't properly redraw their areas..
Completed
Last Updated: 11 Feb 2015 11:58 by ADMIN
ADMIN
Created by: Julian Benkov
Comments: 0
Category: Dock
Type: Bug Report
3
I have issues with Databindings for RadToggleButton and RadDock ToolWindow.

Here are 3 scenarios to try with my repro application.

ToggleButton
Click the radToggleButtonElement1, notice that the binding never occurs.

ToolWindow Docking issue 1
Dock the toolWindow1 to the left over ToolWindow2
Click toolWindow2
Click toolWindow1
Click toolWindow2
Notice each time you click another tool window, the binding is triggered even if the property value hasn't changed.

ToolWindow Dockin issue 2
Dock the toolWindow1 to the left over toolWindow2
Notice that the binding is triggered, but with the previous value (Floating instead of Docked)
close the toolWindow1
Notice that the binding is triggered, but with the previous value (Docked instead of Hidden)
Completed
Last Updated: 06 Feb 2015 15:31 by ADMIN
The issue is reproduced when the Theme service of Windows is stopped and classic windows desktop is used
Completed
Last Updated: 27 Aug 2015 14:37 by ADMIN
ADMIN
Created by: Julian Benkov
Comments: 3
Category: Dock
Type: Feature Request
3
support of Pin tab operation in DocumentContainer of RadDock
Completed
Last Updated: 06 Feb 2015 13:03 by ADMIN
ADMIN
Created by: Telerik Admin
Comments: 0
Category: Dock
Type: Feature Request
3
There should be a method which allows the user to host a Form in a HostWindow. This will come in handy when there is a save/load layout scenario.

Resolution: 
Use the DockControl method to host a form. Here is the code snippet: 
Form form = new Form8();
this.radDock1.DockControl(form, Telerik.WinControls.UI.Docking.DockPosition.Left);
Completed
Last Updated: 18 Feb 2015 14:57 by ADMIN
Currently, it is not possible to add any RadElement to a TabStripItem in DocumentTabStrip.

Resolution: 
Use the static class RadDockEvents to subscribe to events before InitializeComponent
1 2 3 4 5 6