Completed
Last Updated: 17 Mar 2015 14:48 by ADMIN
ADMIN
Created by: Anton
Comments: 0
Category: Dock
Type: Feature Request
2
RadDock - implement BackgroundImage property.
Completed
Last Updated: 04 Apr 2013 03:23 by ADMIN
RadDock - when loading layout, the control reads the stream from the current position instead from the beginning of it. This lead to exception "Root element is missing".

Steps to reproduce:

Dim strmDock As New MemoryStream

RadDock1.SaveToXml(strmDock)
RadDock1.LoadFromXml(strmDock)


Work around:
stream.Position = 0;
Completed
Last Updated: 23 Apr 2014 12:56 by ADMIN
ADMIN
Created by: Alexander
Comments: 0
Category: Dock
Type: Bug Report
2
The keyboard shortcuts should be executed according to the active RadDock control.
Completed
Last Updated: 23 Apr 2014 12:56 by Jesse Dyck
ADMIN
Created by: Alexander
Comments: 1
Category: Dock
Type: Bug Report
2
The issue could be observed in a scenario with nested RadDock controls. An exception is received when the window state is changed to AutoHide.
Completed
Last Updated: 23 Apr 2014 12:56 by ADMIN
ADMIN
Created by: Alexander
Comments: 0
Category: Dock
Type: Bug Report
2
The exception occures when the parent form is minimized.
Completed
Last Updated: 23 Apr 2014 12:56 by ADMIN
ADMIN
Created by: Alexander
Comments: 0
Category: Dock
Type: Bug Report
2
The AutoHide popup is not shown in the scenario, demonstrated in the attached to the forum thread project.
Completed
Last Updated: 02 Feb 2015 10:00 by ADMIN
When the DockWindowClosing event is fired, the ActiveWindow has already been changed.
Completed
Last Updated: 07 Sep 2012 07:57 by ADMIN
When you place RadDock with AutoHideAnimation set to None, add several auto-hide windows and you switch between them, you will notice a flickering at the moment of the change.
Completed
Last Updated: 16 Jan 2015 07:29 by ADMIN
Description: for example if we have two auto-hidden Tool windows (left and right), first click on the right one but don't pin it, then click on the left one (don't pin it also) and you will notice that for a fraction of time its caption displays the text of the previous window. Then you can click the right window again and you'll see the opposite effect. This tiny fraction of time raises to a significant period of time when tool windows are loaded with multiple controls. AutoHideWindowDisplaying event fires before ActiveWindowChanged event (AutoHideTabStrip.ActiveWindow is the other tool window during AutoHideWindowDisplaying). That is why for a fraction of time (during AutoHideWindowDisplaying event) you can see different caption text. To reproduce: - add RadDock - add two auto-hidden Tool windows (left and right) - first click the right one in order to display the hidden tool window -> for a fraction of time its caption is for the other tool window Workaround: private void radDock1_AutoHideWindowDisplaying(object sender, AutoHideWindowDisplayingEventArgs e) { AutoHideTabStrip autoHide = e.NewWindow.DockTabStrip as AutoHideTabStrip; if (autoHide != null) { autoHide.ActiveWindow.Text = e.DockWindow.Text; } }

Another possibility to reduce the flicker is to stop the animations: 

radDock1.AutoHideAnimation = AutoHideAnimateMode.None;
Completed
Last Updated: 21 Feb 2012 04:58 by ADMIN
ADMIN
Created by: Julian Benkov
Comments: 0
Category: Dock
Type: Feature Request
2
I've discovered a behavioral issue with the tool-window when one of its containing control's data-binding is updated.

I'm designing an application using the MVVM design pattern with a basic View and View-Model. The View is a form that contains a RadDock, ToolWindow containing a Label, and a Button to update the Label's Text; and data-binding setup to the ToolWindow's property "DockState" and a Label's property "Text". The View-Model contains the bound properties "ToolWindow1DockState" and "Label1Text", which implements INotifyPropertyChanged to update the respective controls; and a method used to update Label1's text.

After I click "Auto-hide" on ToolWindow1 and click the "Change Text" button, I'm expecting ToolWindow1 to remain in the Auto-hide state. Instead, ToolWindow1 is placed in the Docked state.
Approved
Last Updated: 15 Aug 2017 09:33 by ADMIN
Currently tool windows cannot be re-sized proportionally in this scenario.
Completed
Last Updated: 16 Apr 2012 13:59 by Jesse Dyck
In the test scenario the Autohide Windows is hosted in parent RadDock floating windows.

The ToolWindow in AutoHide dockstate disposed,
after docking the main ToolWindow to tab mode, in a specific scenario.
Completed
Last Updated: 26 Mar 2015 08:51 by ADMIN
Declined
Last Updated: 20 Feb 2014 10:01 by ADMIN
The problem can be reproduced in some scenarios for other controls like RadGridView
Comment: the issue cannot be reproduced!
Completed
Last Updated: 10 Oct 2018 09:23 by Moshe
Having a 
RadDock control put in a simple RadForm, if in execution time we add a ToolWindow control
 to this RadDock and, in that very moment that the tool window is being painted,
 we alternate between two or more applications using "Alt+Tab" keys repeteadly 
and in a fast way, my application crashes generating an "NullReferenceException". 
The original exception trace is as follows:
 Tipo="NullReferenceException" Mensaje="Referencia a objeto no establecida como instancia de un objeto.
" Source="Telerik.WinControls.RadDock" Trace=" 
en Telerik.WinControls.UI.Docking.RadDockCommandManager.CanProcessMessage(Message msg)

 en Telerik.WinControls.UI.Docking.RadDockCommandManager.Telerik.WinControls.IMessageListener.PreviewMessage(Message& msg)
 
en Telerik.WinControls.RadMessageFilter.NotifyGetMessageEvent(Message& msg)
 en Telerik.WinControls.RadMessageFilter.GetMessageHookProc(Int32 code, IntPtr wParam, IntPtr lParam)
 en System.Windows.Forms.UnsafeNativeMethods.GetMessageW
(MSG& msg, HandleRef hWnd, Int32 uMsgFilterMin, Int32 uMsgFilterMax)
 en System.Windows.Forms.Application.ComponentManager.System.Windows.Forms.UnsafeNativeMethods.IMsoComponentManager.FPushMessageLoop
(Int32 dwComponentID, Int32 reason, Int32 pvLoopData)
 en System.Windows.Forms.Application.ThreadContext.RunMessageLoopInner(Int32 reason, ApplicationContext context)
 
en System.Windows.Forms.Application.ThreadContext.RunMessageLoop(Int32 reason, ApplicationContext context)
 en System.Windows.Forms.Application.Run(Form mainForm)

Completed
Last Updated: 17 Mar 2015 13:48 by ADMIN
Completed
Last Updated: 02 Feb 2015 08:26 by ADMIN
ADMIN
Created by: Georgi I. Georgiev
Comments: 2
Category: Dock
Type: Bug Report
1
To reproduce:
Add RadMenu, add item, add radshortcut, dock the form as mdi child
Completed
Last Updated: 21 Jul 2011 09:57 by ADMIN
ADMIN
Created by: Jack
Comments: 0
Category: Dock
Type: Feature Request
1
The ShowAutoHidePopup method should enable showing auto hidden pop-ups.
Completed
Last Updated: 06 Feb 2015 17:28 by ADMIN
ADMIN
Created by: Jack
Comments: 0
Category: Dock
Type: Feature Request
1
Currently it is not possible to customize the tool window animation and there is no animation when closing the tool window.

Resolution: 
Set the AutoHideAnimation and the AutoHideAnimationDuration properties of RadDock 
Completed
Last Updated: 23 Jul 2010 10:08 by ADMIN
ADMIN
Created by: Stefan
Comments: 0
Category: Dock
Type: Bug Report
1