Approved
Last Updated: 05 Apr 2018 12:47 by John
When open a test project in VS 2015 - Update 3 and try to open test file with no data - the following exception occur:

"Object reference not set to an instance of an object."

All other test files with data are opened normally.
The problem is hard to reproduce. 
The workaround is to use different VS version or to attach empty data to a test.
Approved
Last Updated: 04 Apr 2018 11:14 by ADMIN
Steps to reproduce and further environment setup information - in the internal description.
Approved
Last Updated: 04 Apr 2018 10:57 by ADMIN
Steps to reproduce and access to the application are in the internal description.
Won't Fix
Last Updated: 03 Apr 2018 12:15 by ADMIN
Not sure about exact repro. Sometimes when I open a test with coded steps in Visual Studio I get the following error when I try to run it: 

'17-Dec-16 11:23:32 PM' - System.ArgumentException: String cannot have zero length.
   at System.Reflection.RuntimeAssembly.GetType(RuntimeAssembly assembly, String name, Boolean throwOnError, Boolean ignoreCase, ObjectHandleOnStack type)
   at System.Reflection.RuntimeAssembly.GetType(String name, Boolean throwOnError, Boolean ignoreCase)
   at System.Reflection.Assembly.GetType(String name)
   at ArtOfTest.WebAii.Design.Execution.ExecutionUtils.EnsureTypeExists(Assembly assm, String typeName)
   at ArtOfTest.WebAii.Design.Execution.ExecutionUtils.CreateCodedTestInstance(Test test, TestResult result, String binariesFolder)
   at ArtOfTest.WebAii.Design.Execution.ExecutionEngine.InternalExecuteTest(Test test, TestResult initializationResult)
   at ArtOfTest.WebAii.Design.Execution.TestExecuteProxy.ExecuteTest(ExecuteTestCommand command)

Closing the test, rebuilding and opening it again seems to work. But I think this same issue also causes problems when the test suite is deployed on remote machines. 
Approved
Last Updated: 02 Apr 2018 15:26 by ADMIN
To reproduce the problem - first maximize Chrome and then resize the browser in a coded step using the sample line bellow:

ActiveBrowser.Window.Move(new System.Drawing.Rectangle(150, 150, 1000, 700), false);
Approved
Last Updated: 02 Apr 2018 11:40 by ADMIN
When using specific find logic for an anchor element there is a problem to locate the proper element during test execution.

Steps to reproduce and access to the application are in the internal description.
Approved
Last Updated: 02 Mar 2018 10:17 by ADMIN
There is out of memory exception generated when Run - To Here is applied to a step close to the end of the scenario. 
Steps to reproduce and access to the application are in the internal description.
Completed
Last Updated: 26 Feb 2018 13:39 by ADMIN
Steps to reproduce and access to the application are in the internal description.
Won't Fix
Last Updated: 05 Jan 2018 12:45 by Roland
GetRectangle() function call returns invalid X and Y coordinates under special circumstances.

Steps to reproduce and access to the application are in the internal description.
Completed
Last Updated: 21 Dec 2017 08:47 by ADMIN
When steps are renamed in a functional test this change does not take place in a performance run.
Approved
Last Updated: 07 Dec 2017 12:37 by ADMIN
In a scenario where security certificate dialog has to be workaround using a coded step - when exported and executed in Visual Studio using Test Explorer makes IE to crash.
Approved
Last Updated: 01 Dec 2017 08:46 by ADMIN
1) Create a new WPF test
2) Configure the application path
3) Start recording the WPF application
4) Click somewhere in the application
5) View the storyboard

Expected: The storyboard image to be captured
Actual: "Missing preview image"
Completed
Last Updated: 28 Nov 2017 11:46 by ADMIN
If using SimulateRealTyping option after specific step configuration makes Edge execution to stop. I work around is to disable this option. 

Steps to reproduce and access to the application are in the internal description.  
Approved
Last Updated: 08 Nov 2017 14:13 by Briar
Steps to reproduce and access to the application are in the internal description.
Completed
Last Updated: 30 Oct 2017 17:19 by Jeffrey
Created by: Geoffrey Hudik
Comments: 4
Type: Bug Report
3
Databinding to an Excel .xlsx didn't work, it only worked to a .xls file. Considering that format is Office 97-2003 and it's 2016 I'd expect .xlsx to work. At the least I'd expect the app to give me a message stating it isn't supported.

v 2016.2.630.0
Approved
Last Updated: 17 Oct 2017 10:49 by ADMIN
ADMIN
Created by: Nikolay Petrov
Comments: 0
Type: Bug Report
0
The selected results does not publish to the TFS build server to be associated with a specific product build.
Completed
Last Updated: 12 Oct 2017 12:36 by ADMIN
In current product version (R2 2017 SP1) - handle download dialog test step returns exception with Chrome 61.
Approved
Last Updated: 12 Oct 2017 12:32 by ADMIN
This problem is specific for a certain application and Chrome 61 version. Using other browsers or direct execution does not reproduce it.

Steps to reproduce and access to the application are in the internal description.
Completed
Last Updated: 18 Sep 2017 12:07 by ADMIN
Steps to reproduce:
1. Start recording
2. Highlight an element on a page and from quickstep menu select "Add to elements..."
3. Change to the "Element friendly name" dialog (BTW: In nearly all cases the menu appears in the background and you have to know to switch to it - user unfriendly, display it in front)
4. Set name
5. Add a step for the element (e.g. verify that text is something)
Result: 
* In the element explorer is friendly name
* In the step properties (Primary Target) is friendly name
* In the step description is some generated name (e.g. Verify 'TextContent' 'Contains' 'Sign in' on 'IdSSpan').  Where 'IdSSpan' is some generated name not used anywhere and 'SignInText' is friendly name. 
* When I try to reset name, the generated name is stuck. The only way to fix it is to choose again the same element using primary target in step properties.

Expected result:
The name in the step should be friendly name. It makes it pretty hard to discern if I added another element to the page or if an already existing one was used.

I have seen several feedbacks with similar/same problems, but they had comments that it was fixed long time ago so I am submiting a new one.
Approved
Last Updated: 11 Sep 2017 15:05 by Matthias
With the tracelog ON the application can find windows and will run ok (except for the memory leak).If you turn the tracelog off, it will fail after a couple of iterations.(This is the registry key in HKEY_CURRENT_USER\Software\Wow6432Node\Telerik\Test Studio\TraceLogEnabled )

Application and test code to replicate the problem is shared internally.