Approved
Last Updated: 03 Aug 2016 13:55 by Karthick Purushothaman
ADMIN
Created by: Nasko
Comments: 3
Category: PivotGrid
Type: Feature Request
2

			
Approved
Last Updated: 03 Jan 2017 20:54 by ADMIN
This happens when the resizer is moved to max right (for example) and then the orientation is changed. 
Approved
Last Updated: 03 Jan 2017 20:54 by ADMIN
If all RadTileViewItems have their Visibility set  to Collapsed and MinimizedRowHeight or MinimizedColumnWidth properties of the RadTileView are changed, the items cannot be visualized again.
Approved
Last Updated: 03 Aug 2016 13:05 by Veijo
- Add text box and RadGridView to silverlight app
- Add one editable row and multiple read only rows after that to a RadGridView. 
- Go to last cell of first row and double click for edit mode.
- Press tab

Focus should go to text box, instead silverlight hangs.

Find attached sample application where this can be reproduced.
Approved
Last Updated: 31 Oct 2018 07:54 by ADMIN

Workaround: When the error is reproducible with revisions, inherit the RevisionsToolTipLayer class and override ResetPooledElementProperties method
protected override void ResetPooledElementProperties(object element)
{
    if (element is Path)
    {
        Path path = (Path)element;
        path.Data = null;
        path.Fill = null;
        path.Dispatcher.BeginInvoke(()=>
        ToolTipService.SetToolTip(path, null));
    }
}


When the error is thrown when using hyperlinks, setting the format string for hyperlinks to an empty string prevents the error but will also disable the hyperlink tooltips:
this.radRichTextBox.HyperlinkToolTipFormatString = string.Empty;
Approved
Last Updated: 03 Aug 2016 14:52 by Jiri
Approved
Last Updated: 03 Jan 2017 21:09 by Telerik Admin
If you visualize the horizontal grid lines and use CartesianCustomLineAnnotation to differentiate the 0 horizontal line, the annotation is rendered above the 0 grid line. The annotation should be snapped to the 0 thick of the vertical axis.

As a workaround CartesianGridLineAnnotation could be used.
Approved
Last Updated: 29 Dec 2016 15:12 by ADMIN
The expanding of items does not work as expected in a data binding scenario when the CollapseAll()/ExpandAll() methods are used

There is a scenario where the RadTreeView is data bound and its items IsExpanded property is bound to a property from the view model. Then the CollapseAll() and ExpandAll() methods are called. When you try to collapse the treeview items through the property from their view model (that is bound to IsExpanded) only the items in the view port are collapsed.
Approved
Last Updated: 29 Dec 2016 15:21 by ADMIN
The AddedItems in the SelectionChanged handler contains an empty object in some cases when the virtualization is enabled and the virtualization mode is set to Hierarchical.

Approved
Last Updated: 03 Jan 2017 21:09 by ADMIN
The scroll buttons are not correctly displayed when the TabStripPlacement is set to Right and there is no default selection (the IsDefaultItemSelected is set to False).

As a workaround set the RadTabControl's IsDefaultItemSelected property to True or select a RadTabItem manually through its IsSelected property.
Approved
Last Updated: 03 Aug 2016 10:58 by jen
Add Events for when the ClearSelectionButton is clicked.

onSelectionClearingEvent (cancelable preview event)
OnSelectionClearedEvent

This way we can easily handle the clearing of non-nullable datatypes
Approved
Last Updated: 31 Oct 2018 07:54 by Vennila
ADMIN
Created by: Kammen
Comments: 1
Category: PDFViewer
Type: Feature Request
1
Due to Silverlight limitations, currently only the user can specify which pages to be printed. We will consider implementing this custom functionality.
Approved
Last Updated: 31 Oct 2018 08:07 by ADMIN
For now, the static methods of ExtensibilityManager class are the only option to extend all RadPdfViewer instances.
Approved
Last Updated: 03 Aug 2016 13:00 by ADMIN
Approved
Last Updated: 08 Aug 2016 09:24 by ADMIN
The Upload does not pass data set in the args of its FileUploadStarting event. The values set in the args are send only for the first chunk, all chunks after that does not have that data.
Approved
Last Updated: 03 Jan 2017 20:55 by ADMIN
This happens only with editable ComboBox in Silverlight.
Approved
Last Updated: 04 Aug 2016 09:20 by ADMIN
Approved
Last Updated: 27 Dec 2016 13:20 by ADMIN
RadMap with Clustering enabled on Visualization layer. Pushpins whose locations have equal or almost equal Latitudes or Longitudes are shown on particular zoom level (for example 19). You see them when clicking on the cluster. If the MaxZoomLEvel is set to be lower than 19, the pushpins are not placed in their correct positions after clicking on clusters and zooming out with mouse multiple times.
Approved
Last Updated: 03 Aug 2016 13:55 by m l
This is essential for features such as custom calculated measures. Other suppliers such as DevExpress already support this. I think it should be relatively simple as the session ID just needs to be added to the SOAP header for each XMLA query
Approved
Last Updated: 09 Aug 2016 12:23 by ADMIN
Created by: jen
Comments: 2
Category: AutoCompleteBox
Type: Feature Request
1
Expose the Textbox's MaxLength property to limit text input on the RadAutoComplete SearchText Property