VM4197:1 ERROR DOMException: Failed to execute 'setAttribute' on 'Element': 'aria-disabled]' is not a valid attribute name.
Severity: Sev2
Environment (OS, Application, Versions):
OS: Windows11 (build 22631.3296)
Chrome Version 122.0.6261.129 (Official Build) (64-bit)
Chromium Edge Version 122.0.2365.80 (Official build) (64-bit)
AT (include version number):
NVDA Version 2023.3.4. (2023.3.4. 31265)
Jaws (Version 2024.2312.53)
Narrator (Version Win11)
Repro Steps:
1.Turn on NVDA screen reader.
2.Hit the Dropdowns Library - Overview | Kendo UI for Angular (telerik.com)
3.TAB till "AutoComplete" edit combo box and insert "C", suggestion list will expand.
4.Press down arrow key to navigate through expanded list.
5.Observe that NVDA is not announcing the available list items.
Actual Results:
NVDA is not announcing the available suggestion list items of "Auto complete" combo box when we navigate with arrow keys.
Expected Results:
NVDA should announce the available suggestion list items of "Auto complete" combo box when we navigate with arrow keys.
9991592_NVDA_KendoExternal.mp4
When virtual is true for a multiselect and checkboxes are set to true, there is a bug which results in multiple items being selected.
To reproduce, one needs to scroll down a long list of items. The amount to scroll seems random but might have something to do with the itemHeight setting. When clicking directly inside the checkbox, two items are selected at once - the item selected, and one other seemingly random item. This does not happen if the click selection event happens inside the item, but not the checkbox.
I have reproduced this inside this code sandbox: https://codesandbox.io/p/sandbox/mystifying-shirley-2qxn32
Using the Editor component with Form Support, if I choose the style Heading 1 and type some letter.
I clean the value using only backspace key on the keyboard and the value of the form control is <h1></h1>.
This is reproductible on the demo : https://www.telerik.com/kendo-angular-ui/components/editor/forms/#toc-template-driven-forms
Expected result
Dear Kendo-Supportteam,
We are experiencing an issue with the Editor component.
It turns out that setting the iframe input to false causes the paste event to be triggered twice.
Once as documented before the valueChange event and once seemingly as the native paste event after valueChange.
There are multiple issues resulting from this.
It is quite easy to reproduce this from your event demonstration examples by just setting the iframe input to false and maybe also trying to call isDefaultPrevented in the respective paste event handler.
Kind Regards,
Hannah
As demonstrated by the example of the current version and its screenshot, the title of the legend is black when using a dark theme:
Legend - Chart - Kendo UI for Angular (telerik.com)
The rest of the text is white which leads me to believe that this is a bug. This issue is not present when using a light theme.
https://stackblitz.com/edit/angular-mqywpa?file=src%2Fapp%2Fupload.component.ts
When using kendoTooltip directive on the upload component - tooltips are positioned in invalid position somewhere on the app.
cancel, delete, retry tooltips.
https://stackblitz.com/edit/angular-5elhtu?file=src%2Fapp%2Fapp.component.ts
When a detail row is used, the moment you expand one row and scroll, it automatically loads the last items from the dataset.
Ex expand row 1 - start scrolling, and it suddenly loads 5xx th row+;
When grouping is also enabled - expanding the detail row under one group, expands it under all groups.
The stackbliz is from the kendo demo page for virtualscroll (with the added detail row).
If you have a kendo grid table with some data over multiple pages and you go e.g. to the last page and then reload the data, resulting with less pages - the table is empty and you have to manually click on the first page to see the data. Here is a working example:
https://codesandbox.io/s/upbeat-lamarr-d67m8k?file=/src/app/app.component.ts
Step 1. Go to the last page
Step 2. Click on the button "'Reset data" <- you see no data
Step 3. Click on the first page <- You see the data
We are exporting an Excel from a treelist -> there are merged cells, and the table has lots of rows (~20k).
It's taking forever (it's unusable) and the reason is that there is an O(N^2) bug in the toXML function: each row adds a merged cell range, and the mergedCells array is scanned linearly for every new row.
I was able to fix this by adding a mergedCells hash (I would be happy to create a pull request).
Also, as a related issue, it would be nice to be able to change the compression level on the generated zip file, because the default again takes forever for large enough files.
Test Environment:
Windows 11 Enterprise 22H2 22621.1848.
Narrator
Microsoft Edge Version 114.0.1823.79
Repro steps:
Actual Result:
When pressing enter on the column menu present beside the "Contact name" column header of the table, Screen reader is no announcing the state of the the column as it is expanded or collapsed because of the role set as link.
Expected Result:
When pressing enter on the column menu present beside the "Contact name" column header of the table, screen reader should be announcing the state of the column menu as it is expanded or collapsed, role should be set as button with expand collapse functionality.
When printing directly from Angular PDF Viewer results in a blurry printed PDF document. Downloading to PDF and printing does not affect the document
Test Environment:
Browser: Edge browser Version 114.0.1823.51 (Official build) (64-bit)
OS: Windows 22H2
Steps to Reproduce:
Actual Result: Fastpass run shows "Ensures every ARIA input field has an accessible name" error for “Select gender” dropdown.
Expected Result: Every ARIA input field has an accessible name
Fix ONE of the following:
aria-label attribute does not exist or is empty
aria-labelledby attribute does not exist, references elements that do not exist or references elements that are empty
Element has no title attribute
When setting the [zoom] value in TypeScript the drop down value does not reflect this and remains at the default of 125% even though the PDF is zoomed in/out.
Adjusting the zoom level using the buttons then "corrects" the issue and it displays the right value.
Fix ONE of the following:
Required ARIA children role not present: group, option
Element has no aria-busy="true" attribute
When an assistive technology encounters an element with an invalid ARIA attribute value, it might ignore the attribute or respond to it in an unexpected way. As a result, people who use assistive technologies might find the element difficult or impossible to use.
Fix ONE of the following:
Required ARIA children role not present: group, option
Element has no aria-busy="true" attribute