Completed
Last Updated: 20 May 2019 11:52 by ADMIN
ADMIN
Created by: Danail Vasilev
Comments: 5
Category: Button
Type: Feature Request
19
You can configure the confirm dialog through a ConfirmText property that defines the confirmation text. The boolean result can be exposed in the arguments of the click event. If there is a RadWindowManager on the same page a radconfirm should be used otherwise - the browser one.

For the time being the functionality can be achieved manually as illustrated in this demo - http://demos.telerik.com/aspnet-ajax/button/examples/confirm/defaultcs.aspx
Approved
Last Updated: 20 Feb 2018 15:37 by Peter
ADMIN
Created by: Pero
Comments: 2
Category: Button
Type: Feature Request
8
Improve the SplitButton functionality so it is easier to use. Also provide a way for easier integration of ContextMenu with SplitButton as shown in the following demo: http://demos.telerik.com/aspnet-ajax/button/examples/splitbutton/defaultcs.aspx
Completed
Last Updated: 19 Jun 2015 16:00 by Tony
Completed
Last Updated: 27 Feb 2013 12:30 by Eli
When a RadButton with configured ValidationGroup is used on a master page its server-side event 'Click' is not raised in:
-Internet Explorer and Chrome, but FireFox and Opera.
-In all browsers when the master page contains a RadAjaxManager.
Approved
Last Updated: 03 Sep 2013 13:30 by ADMIN
When a RadButton is clicked and the following conditions are met:
    -Page validation is not passed
    -Button's postback is cancelled in OnClientClicking event by setting args.set_cancel(true)
the postback of other RadButtons will not be performed.
Completed
Last Updated: 03 May 2016 14:02 by ADMIN
ADMIN
Created by: Ivan Danchev
Comments: 0
Category: Button
Type: Bug Report
5
Reproduced with latest official (2016.1.113) and internal (2016.2.128) in all browsers. Not reproducible with 2015 Q3 SP1.

Code to reproduce the problem:

    <asp:Button runat="server" ID="GoStep2" OnClick="GoStep2_Click" Text="Next" />
            <asp:Panel runat="server" ID="Panel1">
                <asp:Button Text="aspButton" runat="server" />
                <telerik:RadButton ID="Button1" Text="radButton" runat="server" />
            </asp:Panel>
 protected void Page_Load(object sender, EventArgs e)
    {
        Panel1.Enabled = false;
    }
 protected void GoStep2_Click(object sender, EventArgs e)
    {
        Panel1.Enabled = true;
    }


1 click the Next  button

3. When the page loads after the postback the RadButton remains disabled, unlike the asp:Button. 
Approved
Last Updated: 11 Nov 2015 00:13 by Ikbum Kim
Completed
Last Updated: 11 Jan 2017 07:09 by ADMIN
Code that reproduces the issue:

        <asp:TextBox ID="Textbox1" runat="server" ValidationGroup="vg1" />
        <telerik:RadButton ID="RadButton1" runat="server" ValidationGroup="vg1" Text="click" />
        <asp:RequiredFieldValidator ID="Requiredfieldvalidator1" ErrorMessage="text box is empty" ControlToValidate="Textbox1" ValidationGroup="vg1" runat="server" />
        <asp:ValidationSummary ID="Validationsummary1" runat="server" ValidationGroup="vg1" ShowMessageBox="true" />
Completed
Last Updated: 17 Aug 2018 14:35 by Vasssek
Common scenario is to use PrimaryIconCssClass and SecondaryIconCssClass to decorate custom icons. Common situation is using bootstrap's classes for the glyphicons.

In order to workaround this you can use custom CSS rules and define the expected content properties for the before elements. This is an example with bootstrap icons (http://glyphicons.bootstrapcheatsheets.com/). 


<style>
    .rbPrimaryIcon.glyphicon-filter:before,
    .rbSecondaryIcon.glyphicon-filter:before {
        content: "\e138";
    }
</style>

<telerik:RadButton ID="RadButton2" runat="server" 
    Text="Filter" ButtonType="SkinnedButton" 
    Icon-PrimaryIconCssClass="glyphicon glyphicon-filter" >
</telerik:RadButton>

Completed
Last Updated: 21 Apr 2017 14:10 by ADMIN
Workaraounds:
- Use the Lightweight RenderMode
- OR, use the RadCheckBox control instead

Steps to reproduce:

			<telerik:RadSkinManager runat="server" ID="rsm1" ShowChooser="true"></telerik:RadSkinManager>
			<telerik:RadButton ID="rbFileLink" runat="server" ToggleType="CheckBox" ButtonType="ToggleButton"
							   Checked="true" AutoPostBack="false">
			</telerik:RadButton>
Completed
Last Updated: 23 Feb 2015 15:30 by sharath
Completed
Last Updated: 15 Jan 2016 17:09 by ADMIN
Completed
Last Updated: 29 Sep 2015 10:20 by Dan
When the PrimaryIconUrl and PrimaryHoveredIconUrl properties of the RadButton are set and a dialog is opened when OnClientClicked event is triggered, the button's icon from the hovered image persists. This behavior is observed only in FireFox.
Completed
Last Updated: 11 May 2015 09:53 by Elena
Currently when the RadButton is used as an Image button:

- There is a flickering on mouse over and mouse out.

- During the postback the image of the current or other image buttons disappears on mouse over/mouse out.

The unexpected behavior is observed under Chrome and page is hosted on Cassini. It is caused due to the image requests that Chrome does for each state of the RadButton - normal and hovered.
Completed
Last Updated: 10 Jun 2015 14:07 by eBuild
ADMIN
Created by: Danail Vasilev
Comments: 3
Category: Button
Type: Bug Report
2
SharePoint 2013 applies global styles to the inputs that affect the appearance of the RadButtons.For the time being the styles that SharePoints sets to the inputs can be overriden:

ASPX:
<telerik:RadButton ID="RadButton1" runat="server" Text="RadButton"><Icon PrimaryIconCssClass="rbAdd" /></telerik:RadButton>

CSS:
<style type="text/css">
    .RadButton.RadButton_Default.rbSkinnedButton input {
        padding: 0px 10px 0px 25px;
        border: none;
        margin-left: 0px;
    }
</style>
Completed
Last Updated: 03 Sep 2013 13:29 by Michael
RadButton peforms duplicate requests when:

- A RadButton exists on the page and the form is submitted when a text box is focused and enter key is hit.
- the defaultbutton property of the form is set to the id of the RadButton

For the time being the following functions' override can be used:

        <script type="text/javascript">
            Telerik.Web.UI.RadButton.prototype._isButtonActiveElement = function (eventTarget) {
                var doc = eventTarget && eventTarget.ownerDocument ? eventTarget.ownerDocument : document;
                var activeElement = doc.activeElement;
                if (!activeElement)
                    return false;
                if (activeElement === this.get_element() || $telerik.$.contains(this.get_element(), activeElement))
                    return true;
                return false;
            }

            var originalMouseClickHandler = Telerik.Web.UI.RadButton.prototype._mouseClickHandler;
            Telerik.Web.UI.RadButton.prototype._mouseClickHandler = function (args) {
                if (!this.get_enabled() || this.get_readOnly()) {
                    $telerik.cancelRawEvent(args.rawEvent);
                    return false;
                }

                var eventTarget = args.target ? args.target : args.srcElement;
                if (eventTarget === this.get_element() && !this._isButtonActiveElement(eventTarget) && !$telerik.isTouchDevice) {
                    $telerik.cancelRawEvent(args.rawEvent);
                    this.focus();
                    return false;
                }
                originalMouseClickHandler.call(this, args);
            }
        </script>

The workaround must be placed after the declaration of the RadButton, in order to take effect.
Completed
Last Updated: 10 Dec 2013 07:39 by ADMIN
In Q3 2013 the clicking of RadButton is not raised when Enter key is pressed inside a password TextBox and the RadButton is set to be the default button for the form.

The workaround is to put the following JavaScript code below the declaration of the RadButton:

                                        <script type="text/javascript">
                                            Telerik.Web.UI.RadButton.prototype._isInputTypeText = function (element) {
                                                var nodeName = element.nodeName,
                                                  type = element.type;
                                                if (nodeName != "INPUT" || !type) return false;
                                                return type == "text" || type == "password" || type == "email" || type == "number" || type == "url" || type == "search" || type == "tel";
                                            }
                                        </script>
Approved
Last Updated: 20 Sep 2013 07:42 by Puriwat
RadButton's clicking is triggered when the following conditions are met:

-input type="text" handles onkeypress event

-onkeypress event focuses the RadButton

-the key pressed that is handled by onkeypress event is Space or Enter

Triggering the clicking with "Space" can be workaround by setting some timeout to the focus(). For example:

ASPX:

        <telerik:RadButton ID="RadButton1" runat="server" Text="RadButton"></telerik:RadButton>
        <input type="text" name="name" value=" " onkeypress="KeyPressed();" />

JavaScript:

        function KeyPressed() {
            setTimeout(function () {
                $find("RadButton1").focus();
            }, 200);
        }

Under Review
Last Updated: 22 Mar 2017 18:35 by Yasha
When multiple RadButtons (ButtonType="ToggleButton" ToggleType="Radio") are grouped through GroupName property, the server-side property checked doesn't take effect when the button which is to be checked is declared before the current checked button.

The workaround is to execute JavaScript from the server which sets the checked property. For example:

C#:

        string script = "function f(){$find(\"" + RadButton1.ClientID + "\").set_checked(true); Sys.Application.remove_load(f);}Sys.Application.add_load(f);";
        ScriptManager.RegisterStartupScript(this, this.GetType(), "key", script, true);

Approved
Last Updated: 03 Jul 2014 14:40 by Rick Atkinson
If the Target property of the RadButton (ButtonType="LinkButton") is set to a custom string (the name of the target window, where the content of the linked page will be rendered), the link is not opened. For the time being the following workaround can be used:

JavaScript:

    <script>
        function OnClientClicked(sender, args) {
            var target = sender.get_target();
            var navURL = sender.get_navigateUrl();
            window.open(navURL, target)
        }
    </script>

ASPX:

<telerik:RadButton ID="RadButton1" runat="server" ButtonType="LinkButton" Text="click" Target="MyWindow" NavigateUrl="http://www.google.com" OnClientClicked="OnClientClicked" />
1 2 3 4 5