Completed
Last Updated: 24 Jul 2013 07:59 by ADMIN
The icon shown in the predefined dialogs can be changed with an argument that points to the new image as shown in this demo: http://demos.telerik.com/aspnet-ajax/window/examples/browserdialogboxes/defaultcs.aspx. This does not work with RenderMode=Lightweight
Completed
Last Updated: 01 Jul 2013 07:27 by ADMIN
When a textbox is focused pressing enter will have the browser click the first available button in the form, which is, in this case the first command button from the RadWindow.
If the only available command button is Close the RadWindow will close. 

Pressing enter with a textbox focused fires the next button on the form (you can see this with a simple textbox and button without anything special at all) and the page will be posted):
<asp:TextBox ID="Textbox2" runat="server" />
<button onclick="alert(2);" id="testButton">test button</button>
Since the RadWindow is the first thing rendered in a form the first button from its titlebar gets fired when the textbox is inside its ContentTemplate and enter is pressed.


One of the most suitable workarounds is to add a Pin button and cancel the Pin command:
		function OnClientCommand(sender, args)
		{
			if (args.get_commandName() == "Pin")
			{
				args.set_cancel(true);
				$telerik.$(".rwPinButton", sender.get_popupElement()).blur();
			}
		}
where this is attached to the OnClientCommand event of the RadWindow:
	<telerik:RadWindow ID="RadWindow1" runat="server" OpenerElementID="Button1" RenderMode="Lightweight"
		Behaviors="Pin, Move, Close"  OnClientCommand="OnClientCommand">
		<ContentTemplate>
			<asp:TextBox ID="Textbox1" runat="server" />
		</ContentTemplate>
	</telerik:RadWindow>
	<asp:Button ID="Button1" Text="open the RadWindow" runat="server" />
Declined
Last Updated: 01 Nov 2013 13:06 by ADMIN
In IE only (not Chrome), beginning with the Q2 2013 release, an error is thrown on a RadWindow with the EnableShadow="true" property if .hide() is called on the window before it is made visible.  This is new behavior with Q2 2013.  The affected line is:

}else{Sys.UI.DomElement.removeCssClass(this.container,"rwShadow");

where .container = nothing

Current workarounds are:

1. Set EnableShadow="false"
or
2. Make sure that radwindow.isVisible() === true prior to calling .hide()
Completed
Last Updated: 05 Jul 2013 12:03 by ADMIN
A custom icon is replaced with the default icon in the LightWeight renderMode. For the time being the custom icon can be forced by using the OnClientShow event of the control:
		function OnClientShow(sender)
		{
			sender.set_iconUrl(sender.get_iconUrl());
		}
Completed
Last Updated: 24 Jul 2013 07:58 by ADMIN
Possible workarounds:
1) the following CSS rule:
		.rwExternalContent iframe
		{
			height: 100%;
		}

OR

2) some JavaScript attached to the OnClientPageLoad event of the control:
			function OnClientPageLoad(sender)
			{
				sender.get_contentFrame().style.height = "100%";
			}
Completed
Last Updated: 05 Jul 2013 12:52 by ADMIN
If the content page has a title RadWindow should set it for its own title, unless its Title property has been set explicitly.

Since Q2 2013, when ShowContentDuringLoad=true (which is the default value) this does not happen.

The second workaround is using the OnClientPageLoad event:
			function OnClientPageLoad(sender)
			{
				try
				{
					var pageTitle = sender.get_contentFrame().contentWindow.document.title;
					sender.set_title(sender.get_title() == "" ? pageTitle : sender.get_title());
				}
				catch (err)
				{

				}
			}
The try-catch block is used to catch errors in case the page is from another domain and the JavaScript same-origin policy is in effect.

The event handler can also be attached to the RadWindow manager so that it will be used for all its RadWindows.
Completed
Last Updated: 06 Jun 2016 09:59 by ADMIN
Instead, the dimensions the popup will have when restored are returned. This is so because a maximized RadWindow will resize with the browser.

A possible workaround is using the Telerik Static Client Library: http://www.telerik.com/help/aspnet-ajax/telerik-static-client-library.html

			var wnd = $find("RadWindow1");
			wnd.maximize();
			var bounds = $telerik.getBounds(wnd.get_popupElement());
			alert(bounds.width);
Pending Review
Last Updated: 19 Oct 2015 14:52 by tony
Created by: tony
Comments: 0
Category: Window
Type: Bug Report
0
I have a radwindow which opens as a modal popup when a button is clicked, in the initial stages the rad window was able to be dragged towards right and bottom, of the screen, even out of the screen bounds, i managed to fix that by setting the KeepInScreenBounds="true" RestrictionZoneID="dvContainerMain", where "dvContainerMain" is the main div within which all the parent controls come
but now when i resize the parent browser window to almost size less than radwindow size, rad window seems to behave weird, am not able to resize the radwindow even if the resize behavior  is set
Please let me know on this issue, 
seems like there is a bug when the RestrictionZoneID width is less than or close to the radwindow size 

Thanks
Tony Thomas
Unplanned
Last Updated: 28 Mar 2016 07:22 by ADMIN
When the input inside RadWindow is focused the on-screen keyboard is shown, the page is scrolled so the input is into view above the keyboard and then the keyboard hides automatically. This is caused by using a RestrictionZone. Remove this property to avoid the behavior.
Unplanned
Last Updated: 04 Sep 2013 08:19 by Jason
Created by: Jason
Comments: 0
Category: Window
Type: Bug Report
0
When using DOCTYPE //W3C//DTD XHTML 1.0 Strict//EN and setting height to 100px 
RadWindow AutoResize=True gives problems in IE10 by adding unnecessary scrollbars, and in Chrome, FF and Safari the window is to high (approx. 55px too much).

Refers to forum entry: http://www.telerik.com/community/forums/aspnet-ajax/window/autosize-behavior-question.aspx
(I used the same sample project to replicate the problem).

 Please see attached screenshot and project.
Completed
Last Updated: 29 Sep 2014 12:30 by ADMIN
ADMIN
Created by: Marin Bratanov
Comments: 1
Category: Window
Type: Bug Report
24
Currently a page loaded through HTTPS will throw a warning that unsecure content is loaded if the IconUrl of the RadWindow is set with a relative path. This happens because the framework sets the URL without regard for the protocol. A workaround is to always use full urls (e.g. https://mysite.com/images/myIcon.jpg).

If possible, RadWindow should check the protocol and fix the URL so that such warnings are not shown.
Completed
Last Updated: 23 Nov 2015 10:52 by ADMIN
There are several ways to work around this:
1) disable autosizing (set AutoSize to false)
2) move the RadWindow after autoziging finishes (see attached example for a demo):
			function OnClientAutoSizeEnd(sender, args)
			{
				var wndBounds = sender.getWindowBounds();
				//this is the case when the viewport is not sufficient for the RadWindow
				//so the RadWindow is as tall as the viewport
				if (wndBounds.height == $telerik.getClientBounds().height)
				{
					sender.moveTo(wndBounds.x - 9);
				}
			}

3) avoid autosizing for the subsequent page loads in the content page.
This can be done by setting AutoSize to false and additionally the following function attached to the OnClientPageLoad event will provide autosizing for the first load without positioning issues:
 			function OnClientPageLoad(sender, args)
			{
				if (!sender.hasBeenShown)
				{
					sender.autoSize(false);
					sender.hasBeenShown = true;
				}
			}

4)  use partial postbacks in the content page so that it is not fully reloaded and the autosizing logic is not fired again automatically.
Completed
Last Updated: 08 Jun 2016 14:53 by ADMIN
Currently the video does not play, only audio is heard. If autosizing is disabled the video functions properly.
A possible workaround is to disable autosizing and manually call the autosize() method when the page is loaded for all other browsers:

<telerik:RadWindow runat="server" ID="rw1" VisibleOnPageLoad="true" NavigateUrl="PlayVideo.aspx"
    AutoSize="false" Width="700" Height="500" OnClientPageLoad="OnClientPageLoad">
</telerik:RadWindow>

 and

function OnClientPageLoad(sender, args)
{
    setTimeout(function ()
    {
        if (!$telerik.isMobileSafari)
        {
            sender.autoSize(false);
        }
    }, 0);
}
Completed
Last Updated: 27 Jun 2016 08:45 by Tonino
This is related to a browser bug in accessing the document.activeElement property inside an iframe under IE9 and IE10.

See this KB article for additional information and examples: http://www.telerik.com/support/kb/aspnet-ajax/window/modal-radwindow-in-radwindow-in-ie9-and-ie10.aspx .

There are several possible workarounds:
1) remove the Modal feature.
2) Replace the opening logic with the one from this thread ( http://www.telerik.com/community/forums/aspnet-ajax/window/opening-radwindow-from-the-server.aspx ) and add a small timeout before showing the RadWindow. Even 0ms could suffice so the browser has an active element
3) Replace the RadAjaxPanel with an ASP UpdatePanel with UpdateMode set to Conditional
4) Add a function that will provide a focused element and call it in the OnClientBeforeShow event of the RadWindow
5) Add that function and call it in the ResponseScripts of the RadAjaxPanel
 The function could look like this: function fixIE() { document.documentElement.focus();} where, of course, you can focus some other element on the page.

A sample is attached.
Completed
Last Updated: 18 Mar 2015 06:08 by ADMIN
Completed
Last Updated: 16 Apr 2015 15:20 by Elena
Declined
Last Updated: 13 Oct 2014 14:25 by ADMIN
1 2 3 4